If the self-test detects a fault in the EPIRB module, the test indicator LED will start flashing at
the end of the test. For fault codes see the table in the Table 5-2.
Note that the extended self-test can only be performed 60 times. After that the self-test will
indicate "maximum number of extended self-tests exceeded".
Position indicator
Test sequence
EXTENDED
SELF-TEST started
Waiting for position
Position achieved
Self-test started
Signals
Tramsmitted
RLS enabled*1
EXTENDED
SELF-TEST
successful
If one of the above tests are unsuccessful, the remaining test sequences will not be performed, and the test indicator will
indicate self-test failure.
Self-test
failure
*1:For EPIRBs with RLS (Return Link System) disabled the RLS indicator will remain off.
*2:See the Table 5-2 for on failure indications.
●●● ●●● ●●●
Triple flashes
On for 1 second
Chapter 5 About Float-free Capsule
RLS indicator
Test indicator
Multiple short
Off periods
On for 1
second
flashes*2
Strobe light
On
On
●●●●
One flash
〇〇〇
Multipule
95