Rs-232 Used As Synchronization Trigger (Input Or Output) - Kongsberg EA640 Installation Manual

Hydrographic single beam echo sounder
Hide thumbs Also See for EA640:
Table of Contents

Advertisement

RS-232 used as synchronization trigger (input or output)

An RS-232 serial line connection using the Request To Send (RTS) and Clear To Send
(CTS) signals is common way to connect the EA640 system to external devices for
synchronization purposes.
Local connection
A
Connection on remote device
B
Female 9-pin D-Subminiature connector
C
Male 9-pin D-Subminiature connector
D
This cable takes the control signals on a RS-232 serial
line, and uses these as an external trigger. It provides
interface with any peripheral unit that requires or controls
transmit/receive synchronization. Note that this cable
does not support all the signals in the standard RS-232 specification.
Note
This synchronization method can only be used with RS-232 communication. You can
only connect two systems together.
Unless otherwise specified, this cable must be provided by the installation shipyard.
Minimum cable requirements
: 2 x 4 x 0.5 mm
Conductors
: Overall braided
Screen
: 60 V
Voltage
Maximum outer diameter
If you need to install a very long cable, increase the cross section.
413764/C
2
: Defined by the plugs and/or the cable gland
Cabling
63