Networking
SINUMERIK ONE offers integrated PROFINET functionality.
PROFINET IO is supported:
• As part of PROFINET, PROFINET IO is a communication concept that is used to implement
modular, distributed applications. PROFINET IO is based on Industrial Ethernet and allows
distributed field and I/O equipment to be connected to the central processing unit.
• 128 PROFINET IO devices can be operated on the NCU as an IO controller.
3.3

Versions

The scalability of the hardware and software – both from a CNC perspective and in terms of
operation – means SINUMERIK ONE can be used in many sectors. The possibilities range from
simple positioning tasks up to complex multi-axis systems.
Application areas and performance
• On the NCU, the number of axes and/or the performance of the drive control can be increased
to 31 axes. This is achieved through the use of the NX modules. The NCU can be expanded
by up to 5 NX modules for increased performance of the drive control and number of axes.
• An NCU 1750 is recommended for maximum dynamic performance and accuracy in mold
making or in the high speed cutting sector.
The following table shows the key characteristics of the various NCU versions:
Table 3-1
DRIVE-CLiQ ports
Axes
NX10.3 / 15.3
TCU
Channels
Mode groups (BAG)
Maximum resolution with SINUMERIK Operate for
NCU
3.4

Ordering data

Table 3-2
System component
NCU 1750
Numeric Control Extension NX15.3 (High Extension)
Numeric Control Extension NX10.3 (Standard Extension)
PP 72/48D PN I/O module
NCU 1750
Equipment Manual, 01/2022, A5E45627807B AE
Versions of the NCU 1750
Order data for system components
6
31 CNC axes (max. 40 axes, incl. PLC axes)
Up to 5
Up to 4
10
10
1920 x 1080px
Article number
6FC5317-5AA00-0AA0
6SL3040-1NB00-0AA0
6SL3040-1NC00-0AA0
6FC5311-0AA00-0AA0
System overview
3.4 Ordering data