Connectable components
12.3 PP 72/48D PN 2/2A PN
Name
Designation
H2
PNSync
H3
PNFault
H4
DIAG1
H5
DIAG2
H6
OVTemp
Note
When the system is booting, LEDs H1, H2 and H3 are lit.
132
Color
Description
Green
Lit: Task system is synchronized to the bus cycle clock.
Not lit: Task system is not synchronized to the bus cycle clock.
Flashes 0.5 Hz: Task system has synchronized to the bus cycle clock and cyclic data ex‐
change is running.
Red
Not lit: Module is operating without error.
Lit: A system error has occurred (faulty module, incorrect parameterization by the PROFI‐
NET controller, etc.).
Green
Reserved
Green
Reserved
Red
Overtemperature display