Type plate
The NX module type plate contains the following basic information:
Figure 12-2
Note
You might need to access the information provided on the side-mounted type plate after the
equipment has been mounted. Since the type plate is located on the right-hand side of the
housing, which is the side typically used to connect to the SINAMICS S120 module, we
recommend that you make a note of the serial number of the NX prior to assembly.
LED displays
Table 12-1
Description of LEDs on the NX10.3 / 15.3
LED
Color
RDY
Off
Green
Red
Orange
NCU 1750
Equipment Manual, 01/2022, A5E45627807B AE
Type plate using the NX10.3 as example
Status
Continuous light
Flashing light 2 Hz
Continuous light
Flashing light 0.5 Hz
Continuous light
Flashing light 0.5 Hz
Flashing light 2 Hz
Description
Electronic power supply outside permissible tolerance range
NX is ready for operation
Writing to SD card of the connected NCU
NX is presently ramping up and at least one fault is present (e.g. RESET,
watchdog monitoring, basic system fault).
Boot error (e.g. firmware cannot be loaded into the RAM)
Firmware loading into RAM
Unable to load firmware into RAM
Firmware CRC fault
Connectable components