Illustration - Siemens SINUMERIK ONE NCU 1750 Equipment Manual

Hide thumbs Also See for SINUMERIK ONE NCU 1750:
Table of Contents

Advertisement

Description

4.2 Illustration

4.2
Illustration
The following diagram shows an NCU with its interfaces, operating control and display elements
(fault and status displays).
Representation of the NCU
Note
Interface X7 is only designed for service purposes, and cannot be used to connect a display.
30
1
-
Spacer
2
-
Option slot (covered)
3
X126
PROFIBUS DP interface
4
-
Type plate 1
5
-
Type plate 2
6
-
7-segment display
7
-
Reset button
8
-
NCK commissioning switch (rotary switch)
X7
Service socket (display port socket)
9
-
Functional ground
10
-
Diagnostics button
11
X55
Slot for an SD card
12
-
PLC mode selector switch (toggle switch)
13
X127
PN/IE Ethernet interface
14
-
LED displays
15
X135
USB interface
16
X125
USB interface
17
X120
2 Ethernet interfaces
X130
18
X150 P1 R
3 PROFINET IO interfaces
X150 P2 R
X160 P1
19
X124
Power supply
20
X122
Digital inputs and outputs
X132
X142
21
X100 - X105 6 DRIVE-CLiQ interfaces
Equipment Manual, 01/2022, A5E45627807B AE