Analog X3 Inputs/Outputs - Siemens SINUMERIK ONE NCU 1750 Equipment Manual

Hide thumbs Also See for SINUMERIK ONE NCU 1750:
Table of Contents

Advertisement

Table 12-46
Digital outputs
High-level voltage (U
Output current I
Voltage with low level (U
Leakage current at low level
Signal delay time T
Maximum switching frequency
Resistive load
Inductive load
Lamp
12.3.4.5

Analog X3 inputs/outputs

Cable specification
• Connectors: 12-pin socket/plug combination
• Cable: shielded
– max. cable length: 30 m
– max. connectable core cross-section: 0.5 mm
Wiring analog inputs/outputs
NOTICE
Shield support
If the analog inputs/outputs are wired, a shielded lead must be used. The shield must be
supported.
Procedure:
1. Strip cable for analog signals.
2. Secure the stripped connection piece of the cable with the shield connection clamp.
NCU 1750
Equipment Manual, 01/2022, A5E45627807B AE
Electrical specification of the digital outputs
)
H
OUT
)
L
PHL
U
= V
- I
× R
1)
H_typical
CC
OUT
ON
V
: Current operating voltage
CC
I
: Output current
OUT
Maximum short-circuit current: 4 A (max. 100 μs, V
R
: Maximum internal resistance = 0.4 Ω
ON
Where demand factor is 100% (all outputs active)
2)
Incorrect connection causes neither high level nor destruction of the outputs.
min.
Standard
V
- 3 V
1)
CC
-
-
-
-
-
50 μA
-
0.5 ms
-
-
-
-
-
-
= 24 V)
CC
2
Connectable components
12.3 PP 72/48D PN 2/2A PN
max.
nominal
V
24 V
CC
250 mA
-
2)
-
Output open
400 μA
-
-
-
100 Hz
-
2 Hz
-
11 Hz
-
145

Advertisement

Table of Contents
loading

Table of Contents