[Failover setup]
Select the operational settings.
On (monitoring): Master recorders are monitored to switch recording of the recorder if an error occurs.
Off (not monitoring): The failover function is not used.
Default: Off (not monitoring)
[Registered information]
Click the [Setup >] button to set the master recorders.
(⇒Refer to "Configure the settings of the monitoring target recorder")
[Update] button
Acquires the state of the master recorders and updates the display.
Available: Monitoring is on-going and recording can be switched if an error occurs.
Not available: Monitoring is not available due to the inconsistency with the version or the licenses, or the
wrong registered information of the master recorder
Suspend: The failover setup is set to Off.
Note:
• When the status indicates Not available, check the version and the number of licenses of the recorder and
match them.
• The [Update] button can be clicked only when the failover operation is set to On.
[Manually execute the failover]
Select a recorder No. and click the [Execute] button to switch the recorder. If the registered information of the
master recorder is changed, it is necessary to save the settings and click the [Execute] button.
Configure the settings of the monitoring target recorder
Set master recorders subject to monitoring.
Click the [OK] button at the end to complete the change of registered information.
Note:
• Monitoring target master recorders are WJ-NX400 series only.
• The recorder whose HDD operation mode (single/Mirroring/RAID5/RAID6) is different from the slave recorder's
HDD operation mode can not be set as the master recorder for monitoring.
• The camera group recording operates according to the camera group recording setting set in the slave
recorder. The camera group recording setting of the master recorder is not inherited.
213