Binder FED 400 Operating Manual

Binder FED 400 Operating Manual

Drying and heating ovens with forced convection and enhanced timer functions
Hide thumbs Also See for FED 400:
Table of Contents

Advertisement

Quick Links

Operating Manual
Translation of the original operating manual
FED / FED-UL (E2)
Drying and heating ovens
with forced convection and enhanced timer
functions
with microprocessor temperature controller
Model
FED 400 (E2)
FED 400-UL (E2)
FED 720 (E2)
FED 720-UL (E2)
BINDER GmbH
 Address: Post office box 102, 78502 Tuttlingen, Germany  Phone: +49 7462 2005 0
 Fax: +49 7462 2005 100  Internet: http://www.binder-world.com
 E-mail: info@binder-world.com  Service Hotline: +49 7462 2005 555
 Service Fax: +49 7462 2005 93 555  Service E-Mail: service@binder-world.com
 Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
 Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
 Service Hotline Russia and CIS: +7 495 988 15 16
Issue 08-2018
Model version
FED400-400V
FED400UL-208V
FED720-400V
FED720UL-208V
Art. No.
9010-0216, 9110-0216
9010-0217, 9110-0217
9010-0218, 9110-0218
9010-0219, 9110-0219
Art. No. 7001-0070

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FED 400 and is the answer not in the manual?

Questions and answers

Summary of Contents for Binder FED 400

  • Page 1  Fax: +49 7462 2005 100  Internet: http://www.binder-world.com  E-mail: info@binder-world.com  Service Hotline: +49 7462 2005 555  Service Fax: +49 7462 2005 93 555  Service E-Mail: service@binder-world.com  Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3 ...
  • Page 2: Table Of Contents

    Content SAFETY ........................4 Legal considerations ........................... 4 Structure of the safety instructions ...................... 4 1.2.1 Signal word panel .......................... 4 1.2.2 Safety alert symbol ........................5 1.2.3 Pictograms ............................. 5 1.2.4 Word message panel structure ...................... 6 Localization / position of safety labels on the chamber ..............6 Type plate ............................
  • Page 3 Maintenance intervals, service ......................32 Cleaning and decontamination ......................33 9.2.1 Cleaning ............................33 9.2.2 Decontamination .......................... 35 Sending the chamber back to BINDER GmbH ................. 36 10. DISPOSAL......................36 10.1 Disposal of the transport packing ..................... 36 10.2 Decommissioning ..........................37 10.3 Disposal of the chamber in the Federal Republic of Germany ............
  • Page 4: Safety

    Understanding and observing the instructions in this operating manual are prerequisites for hazard-free use and safety during operation and maintenance. In no event shall BINDER be held liable for any damages, direct or incidental arising out of or related to the use of this manual.
  • Page 5: Safety Alert Symbol

    WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious (irreversible) injury CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in moderate or minor (reversible) injury CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in damage to the product and/or its functions or of a property in its proximity.
  • Page 6: Word Message Panel Structure

    Prohibition signs Do NOT touch Do NOT spray with water Information to be observed in order to ensure optimum function of the product. 1.2.4 Word message panel structure Type / cause of hazard. Possible consequences. ∅ Instruction how to avoid the hazard: prohibition ...
  • Page 7: Type Plate

    Keep safety labels complete and legible. Replace safety labels that are no longer legible. Contact BINDER Service for these replacements. Type plate The type plate is located on the chamber front behind the door, bottom left-hand. Nominal temp. 300 °C 3,40 kW / 7,4 A 572 °F...
  • Page 8: General Safety Instructions On Installing And Operating The Chambers

    213-850 on safe working in laboratories (formerly BGI/GUV-I 850-0, BGR/GUV-R 120 or ZH 1/119, issued by the employers’ liability insurance association) (for Germany). BINDER GmbH is only responsible for the safety features of the chamber provided skilled electricians or qualified personnel authorized by BINDER perform all maintenance and repair, and if components relating to chamber safety are replaced in the event of failure with original spare parts.
  • Page 9: Intended Use

    Observing the instructions in this operating manual and conducting regular maintenance work (chap. 9) is part of the intended use. WARNING: If customer should use a BINDER chamber running in non-supervised continuous operation, we strongly recommend in case of inclusion of irrecoverable specimen or samples to split such specimen or samples and store them in at least two chambers, if this is feasible.
  • Page 10: Operating Instructions

    The charging material shall not contain any corrosive ingredients that may damage the machine components. Such ingredients include in particular acids and halides. Any corrosive damage caused by such ingredients is excluded from liability by BINDER GmbH. The chambers do not dispose of any measures of explosion protection.
  • Page 11: Chamber Description

    1010-2-10. Chamber description BINDER drying and heating ovens FED are equipped with an electronic PID-controller with digital display. The temperature is indicated with an accuracy of one degree. The chambers are heated electrically and are ventilated by fan-assisted, forced-air circulation. They FED are equipped with a temperature safety device according to DIN12880 (chap.
  • Page 12: Equipment Overview

    Equipment overview Display Set-point value key (10) Selector keys Time management key Switch ON/OFF Lever for ventilation slide Safety device Door handle Switch for interior lighting (with option interior lighting) or Buzzer switch (with option audible over-temperature alarm) (10) Main power switch Figure 3: FED drying and heating oven Completeness delivery,...
  • Page 13: Guidelines For Safe Lifting And Transportation

    Second-hand chambers have been used for a short time for tests or exhibitions. They are thoroughly tested before resale. BINDER ensures that the chamber is technically sound and will work flawlessly. Second-hand chambers are marked with a sticker on the chamber door. Please remove the sticker before commissioning the chamber.
  • Page 14: Location Of Installation And Ambient Conditions

    Location of installation and ambient conditions Set up the chamber on an even and non-flammable surface, free from vibration and in a well-ventilated, dry location and align it using a spirit level. The site of installation must be capable of supporting the chamber’s weight (see technical data, chap.
  • Page 15: Installation

    1800 mm / 70.87 in in length. Nominal voltage ± 10% at the Model Power plug Current type indicated power frequency FED 400 400 V at 50 Hz CEE plug 5-polig FED 720 400 V at 60 Hz FED 400-UL...
  • Page 16: Start Up

    CAUTION The exhaust duct will become hot during operation. Danger of burning. ∅ Do NOT touch the exhaust duct during operation. Start up Turning on the chamber Warming chambers may release odors in the first few days after commissioning. This is not a quality defect.
  • Page 17: Air Change

    Air change Opening the air flap in the exhaust duct serves to adjust the air change. Without connecting a suction plant: • If the air flap is open and the fan is operating, fresh air comes in via aeration gaps. •...
  • Page 18: Display / Entry Of Temperature And Ventilation Set-Points (With Selected Temperature Ramp)

    Press button to return to normal display (actual value display) (automatically after approx. 30 seconds). Adjust the temperature safety device following any changes of the set-point (chap. 7). Display / entry of temperature and ventilation set-points (with selected temperature ramp) If previously a temperature ramp value has been selected (chap.
  • Page 19: Time Functions: Continuous Operation And Timer Operation

    Set the desired fan speed with the buttons The fan speed can be set to a value between 0% and 100%. Wait 2 seconds until the entered value is taken over (display flashing once). Press button to return to normal display / actual value display (automatically after approx. 30 seconds).
  • Page 20: Switching Between Continuous Operation And Timer Operation

    6.3.1 Switching between Continuous operation and Timer operation Press the time management button The controller displays the actual time function. In time function “Continuous operation”, “t1” and “t inf” are displayed alternately. In time function “Timer operation”, “t1” is displayed alternately with the running- down time or “tOff”.
  • Page 21: Setting The Timer Values

    6.3.3 Setting the timer values Press the time management button . The controller indicates its current time function. If necessary, switch to timer operation by button The display alternately shows”t1” and the running-down time or “tOff”: Remaining time (example: 28 minutes) – Timer running down Timer not programmed or run-off “t off”...
  • Page 22: User Level Settings

    User level settings By pressing down button in normal display (actual value display) for 5 sec, you enter the user menu. Settings in this menu affect controller operation. User level overview: Press down button for approx. 5 seconds Select the temperature unit (chap. 6.4.1) Press button Ramp function (chap.
  • Page 23: Temperature Unit Change Between Degrees Celsius °C And Degrees Fahrenheit °F

    6.4.1 Temperature unit change between degrees Celsius °C and degrees Fahrenheit °F If required, the temperature display can be changed as follows: Press down button for approx. 5 seconds. The display alternately shows “unit” and the actual setting of the temperature unit: Use the buttons to set the required unit.
  • Page 24: Chamber Addressing

    Press down button for approx. 5 seconds. The display alternately shows “unit” and the temperature unit: Press again button The display alternately shows “rASd” and the actual setting of the set-point gradient: Set the desired ramp gradient with buttons (set-point gradient in °F or °C acc. to setting in chap.
  • Page 25: Selecting The Timer Function

    Set the required address with buttons You can enter address values between 1 and 30. The set value is automatically adopted after 2 seconds. 6.4.4 Selecting the timer function The controller provides three different timer functions: • Delayed off (setting “0”) After the defined time has elapsed, the heating is turned off.
  • Page 26: Setting The Interface Mode And, If Appropriate, The Printer Interval

    6.4.5 Setting the interface mode and, if appropriate, the printer interval Press down button for approx. 5 seconds. The display alternately shows “unit” and the temperature unit: Press again button The display alternately shows “rASd” and the set-point gradient: Press again button The display alternately shows “Adr”...
  • Page 27: Temperature Programming Example

    Set the desired value from 0 to 255 with buttons The printer intervals via the RS 422 interface can be set between 1 and 255 min. Setting “0” signifies the printer interval set to off. A protocol printer records the temperature data in the set interval. The set value is automatically adopted after 2 seconds.
  • Page 28: Temperature Safety Devices

    Temperature safety devices Temperature safety device class 2 (DIN 12880) The temperature safety device class 2 protects the chamber, its environment and the charging material from exceeding the maximum permissible temperature. Please observe the DGUV guidelines 213-850 on safe working in laboratories (formerly BGI/GUV-I 850- 0, BGR/GUV-R 120 or ZH 1/119, issued by the employers’...
  • Page 29: Temperature Safety Device Class 3.1 (Din 12880) (Option)

    1. Turn the control knob (7) of the safety device using a coin to its end-stop (position 10) (chamber protection). 2. When the set point is reached, turn back the control knob (7) until its trip point (turn it counter-clockwise). 3.
  • Page 30: Disconnectable Audible Over-Temperature Alarm (Option)

    If the safety device has taken over control (identifiable by the red alarm lamp (7a) lighting up and, in case of the option audible alarm with activated buzzer (chap. 7.3), by the buzzer sounding), proceed as follows: • Disconnect the chamber from the power supply. •...
  • Page 31: Options

    Options Communication software APT-COM™ 3 DataControlSystem (option) The chamber is regularly equipped with a serial interface RS 422 that can connect the BINDER communication software APT-COM™ 3 DataControlSystem. The connection to a computer is established using the chamber’s interface via an interface converter RS 422 / RS 232.
  • Page 32: Analog Output For Temperature (Option)

     Ensure all maintenance work is conducted by licensed electricians or experts authorized by BINDER. Ensure regular maintenance work is performed at least once a year. The warranty becomes void if maintenance work is conducted by non-authorized personnel.
  • Page 33: Cleaning And Decontamination

    We recommend taking out a maintenance agreement. Please consult BINDER Service. BINDER telephone hotline: +49 (0) 7462 2005 555 BINDER fax hotline: +49 (0) 7462 2005 93555 BINDER e-mail hotline: service@binder-world.com BINDER service hotline USA: +1 866 885 9794 or +1 631 224 4340 x3 (toll-free in the USA)
  • Page 34 We recommend using the neutral cleaning agent Art. No. 1002-0016 for a thorough cleaning. Any corrosive damage that may arise following use of other cleaning agents is excluded from liability by BINDER GmbH. Any corrosive damage caused by a lack of cleaning, is excluded from liability by BINDER GmbH. CAUTION Danger of corrosion.
  • Page 35: Decontamination

    For chemical disinfection, we recommend using the disinfectant spray Art. No. 1002-0022. Any corrosive damage that may arise following use of other disinfectants is excluded from liability by BINDER GmbH. With every decontamination method, always use adequate personal safety controls.
  • Page 36: Sending The Chamber Back To Binder Gmbh

    Sending the chamber back to BINDER GmbH If you send a BINDER product to us for repair or any other reason, we will only accept the product upon presentation of an authorization number that has previously been issued to you. We will issue an authorization number (RMA number) after receiving your complaint either in writing or by telephone prior to your sending the BINDER product back to us.
  • Page 37: Decommissioning

    (Elektro- und Elektronikgerätegesetz, ElektroG from 20 October 2015, BGBl. I p. 1739) or contact BINDER service who will organize taking back and disposal of the chamber according to the German national law for electrical and electronic equipment (Elektro- und Elektronikgerätegesetz, ElektroG from 20 October 2015, BGBl.
  • Page 38: Disposal Of The Chamber In The Member States Of The Eu Except For The Federal Republic Of Germany

    According to Annex I of Directive 2012/19/EU of the European Parliament and of the Council on waste electrical and electronic equipment (WEEE), BINDER devices are classified as “monitoring and control instruments” (category 9) only intended for professional use“. They must not be disposed of at public collecting points.
  • Page 39: Disposal Of The Chamber In Non-Member States Of The Eu

    10.5 Disposal of the chamber in non-member states of the EU CAUTION Alteration of the environment.  For final decommissioning and disposal of the chamber, please contact BINDER Service.  Follow the statutory regulations for appropriate, environmentally friendly disposal. FED (E2) 08/2018...
  • Page 40: Troubleshooting

    No button was hit for more Repeat entries, enter the values Display from any level. than approx. 30 sec. rapidly. Only qualified service personnel authorized by BINDER must perform repair. Repaired chambers must comply with the BINDER quality standards. FED (E2) 08/2018 page 40/57...
  • Page 41: Technical Description

    (certified since December 1996 by TÜV CERT). All test equipment used is subject to the administration of measurement and test equipment that is also constituent part of the BINDER QM DIN EN ISO 9001 systems. They are controlled and calibrated to a DKD-Standard at regular intervals.
  • Page 42: Fed Technical Data

    12.4 FED technical data Chamber size Exterior dimensions Width, net mm / inch 1234 / 48.58 1234 / 48.58 Height, gross (incl. feet/castors) mm / inch 1022 / 40.24 1528 / 60.16 Depth mm / inch 765 / 30.12 865 / 34.06 Depth gross (incl.
  • Page 43: Equipment And Options (Extract)

    If the chamber is fully loaded, the specified heating up times may vary according to the load. 12.5 Equipment and options (extract) To operate the chamber, use only original BINDER accessories or accessories / components from third-party suppliers authorized by BINDER. The user is responsible for any risk arising from using unauthorized accessories. Chamber size...
  • Page 44 Chamber size Standard equipment (continued) Temperature safety device class 2 acc. to DIN 12880:2007 with   visual temperature alarm   Adjustable ramp function Rear exhaust duct, internal diameter 50 mm / 1,97 inch with   ventilation slide Adjustable air change by means of rear exhaust duct (50 mm) with ...
  • Page 45: Accessories And Spare Parts (Extract)

    12.6 Accessories and spare parts (extract) BINDER GmbH is responsible for the safety features of the chamber only, provided skilled electricians or qualified personnel authorized by BINDER perform all maintenance and repair, and if components relating to chamber safety are replaced in the event of failure with original spare parts.
  • Page 46: Certificates And Declarations Of Conformity

    Certificates and declarations of conformity 13.1 EU Declaration of Conformity FED (E2) 08/2018 page 46/57...
  • Page 47 FED (E2) 08/2018 page 47/57...
  • Page 48 FED (E2) 08/2018 page 48/57...
  • Page 49: Certificate For The Gs Mark Of Conformity Of The "Deutsche Gesetzliche Unfallversicherung E.v." (German Social Accident Insurance) Dguv

    13.2 Certificate for the GS mark of conformity of the “Deutsche Gesetzliche Unfallversicherung e.V.“ (German Social Accident Insurance) DGUV FED (E2) 08/2018 page 49/57...
  • Page 50 FED (E2) 08/2018 page 50/57...
  • Page 51: Product Registration

    Product registration FED (E2) 08/2018 page 51/57...
  • Page 52: Contamination Clearance Certificate

    Contamination clearance certificate 15.1 For chambers located outside the USA and Canada Declaration with regard to safety and health Erklärung zur Sicherheit und gesundheitlichen Unbedenklichkeit The German Ordinance on Hazardous Substances (GefStofV), and the regulations regarding safety at the workplace, require that this form be filled out for all products that are returned to us, so that the safety and health of our employees can be warranted.
  • Page 53 Kind of transport / transporter / Transportweg/Spediteur: Transport by (means and name of transport company, etc.) Versendung durch (Name Spediteur o.ä.) ___________________________________________________________________________________ Date of dispatch to BINDER GmbH / Tag der Absendung an BINDER GmbH ___________________________________________________________________________________ FED (E2) 08/2018 page 53/57...
  • Page 54 We are aware that, in accordance with Article 823 of the German Civil Code (BGB), we are directly liable with regard to third parties, in this instance especially the employees of BINDER GmbH, who have been entrusted with the handling / repair of the unit / component. / Es ist uns bekannt, dass wir gegenüber Dritten –...
  • Page 55: For Chambers Located In The Usa And Canada

    Please complete this form and the Customer Decontamination Declaration (next 2 pages) and attach the required pictures. E-mail to: IDL_SalesOrderProcessing_USA@binder-world.com After we have received and reviewed the complete information we will decide on the issue of a RMA number. Please be aware that size specifications, voltage specifications as well as performance specifications are available on the internet at www.binder-world.us...
  • Page 56 Customer (End User) Decontamination Declaration Health and Hazard Safety declaration To protect the health of our employees and the safety at the workplace, we require that this form is completed by the user for all products and parts that are returned to us. (Distributors or Service Organizations cannot sign this form) NO RMA number will be issued without a completed form.
  • Page 57 4.5 Shipping laws and regulations have not been violated. I hereby commit and guarantee that we will indemnify BINDER Inc for all damages that are a consequence of incomplete or incorrect information provided by us, and that we will indemnify and hold harmless BINDER Inc.