Connecting to the Network
Figure 3-20 Cable Connection to MT-RJ Multimode Fiber-Optic Connectors
MT-RJ port connector
MT-RJ cable connector
Release tab
3. Plug the other end of the cable into the appropriate port on the other device. Some cables may
be terminated at the other end with two separate connectors, one for each fiber-optic strand. In
this case, ensure that the transmit fiber-optic strand is connected to the receive port and the
receive fiber-optic strand to the transmit port.
4. Verify that a link exists by checking that the port RX LED is on (flashing amber, blinking green,
or solid green). If the RX LED is off, perform the following steps until it is on:
a. Verify that the device at the other end of the segment is ON and connected to the segment.
b. If there are separate fiber-optic connections on the other device, check the crossover of the
cables. Swap the cable connections if necessary.
c. Check that the fiber-optic connection meets the dB loss and cable specifications outlined in
the Cabling Guide for multimode mode cabling. To obtain this document, refer to
Documents" in About This Guide.