7.2
Harmonic Current Emissions < 16A
The DLT VS80 tape drive meets or exceeds the harmonic current emissions requirements in
EN 61000-3-2: 1995.
current emissions (equipment input) current up to and including 16A per phase.
Table 7-3. Fluctuating Harmonics
Harmonic Order (n)
3
5
7
9
2 to 10
11 to 40
Table 7-4
lists the EN 61000-3-2:1995 low frequency harmonic emissions limits for Class D
equipment.
Table 7-4. Harmonic Emissions Class D Equipment
Harmonic Order (n)
2
5
7
9
13
11< n < 39 (odd harmonics only)
001597-01 Rev. A09
Table 7-3
lists the EN 61000-3-2:1995 fluctuating harmonics limits for harmonic
Maximum Permissible
Harmonic Current per Watt
(mA/W)
3.4
1.9
1.0
0.5
0.35
3.85/n
May 2004
Harmonic Ratio
0.9%
0.4%
0.3%
0.2%
0.2%
0.1%
Maximum Permissible
Harmonic Current (A)
2.3
1.14
0.77
0.40
0.33
0.15 x 15/n
DLT VS80 Product Specification