7.3.3
Fast Transient Immunity
Table 7-7
lists the EN 61000-4-4:1995 fast transient immunity limits.
Table 7-7. Fast Transient Immunity
Parameter
AC Mains ± 1 kV
Signal Port (L > 3m) ± 500V
7.3.4
Surge Immunity
Table 7-8
lists the EN 61000-4-5:1995 surge immunity limits.
Table 7-8. Surge Immunity
Parameter
Common/Differential Mode
AC Mains + 2 kV/+ 1 kV
7.3.5
Conducted Immunity
Table 7-9
lists the EN 61000-4-6:1996 conducted immunity limits.
Table 7-9. Conducted Immunity 0.150 to 80 MHz
Parameter
0.150 – 80 MHz, 1 kHz (80% AM), 3V
7.3.6
Power Frequency Magnetic Field Immunity
Table 7-10
Table 7-10. Magnetic Field Immunity
Parameter
50 Hz, 1 A/m
001597-01 Rev. A09
lists the EN 61000-4-8:1993 magnetic field immunity limits.
Performance Criteria
No operator intervention
(soft recoverable errors allowed)
Performance Criteria
No operator intervention
(soft recoverable errors allowed)
Performance Criteria
No errors allowed
Performance Criteria
No errors allowed
May 2004
DLT VS80 Product Specification