• Status DO 2
Bit
Symbol
0
S_ZPASS
1
2
3
S_ZSP
4
S_VLC
5
6
7
8
S_PC
9
10
11
12
13
14
15
S_ZP2
• Status DO 3
Bit
Symbol
0
1
2
3
4
5
S_STO
6
7
8
9
S_RSTP
10
11
S_MTTR
12
13
14
15
2 APPENDIX
42
2.1 CC-Link IE TSN
Description
Z-phase already passed
After the Z-phase is passed, S_ZPASS turns on.
The value at reading is undefined.
Zero speed detection
Limiting speed
The value at reading is undefined.
Proportional control in progress
S_PC is turned on under proportional control.
The value at reading is undefined.
Homing completion 2
When homing finishes successfully, S_ZP2 turns on.
Description
The value at reading is undefined.
In STO state
S_STO turns on in STO state.
The value at reading is undefined.
During forced stop deceleration
During forced stop deceleration, S_RSTP is on.
The value at reading is undefined.
Transition to tough drive mode in progress
The value at reading is undefined.
Reference
Refer to "Signal (device)
explanations" in the following
manual.
MR-J5 User's Manual
(Hardware)
Reference
Refer to "Monitor signal (digital)
[G]" in the following manual.
MR-J5 User's Manual
(Function)
Refer to "Tough drive function" in
the following manual.
MR-J5 User's Manual
(Function)