REMOTE CONTROL SETTING and OPERATION

Transmitter Operation

Remove the battery cover from the remote control transmitter and install
battery, battery provided. Replace the cover.
Note: Use 2 1.5V/AAA battery.
Note: If not using for long period of time, remove battery to prevent damage
to remote transmitter, and store the remote transmitter away from excess
heat or humidity.
Universal Mode and Learning Mode
There are "Universal Mode" and "Learning Mode" with the remote controller.
If choosing "Universal Mode", simply place dip (code) switch at UPPER
position. Your fan with the remote controller is ready to use.
Note: If using universal mode, your fan can be controlled with other remote
transmitters with the same setting.
To control the fan with specific remote transmitter, choose "Learning Mode"
by placing the dip (code) switch at LOWER position and then make learn
function setting as below.
Learn function setting
Important: Turn the power on for ONLY the specific fan you wish to pair with
the remote controller. Make sure to turn the power off for all other fans with
which you use the same remote controller.
Restore power source to your fan, press and hold the "LEARN" button for at
least 3 seconds. You must press the "LEARN" button within 60 seconds of
restoring power to the fan.
Note: If the power is on already, you must turn the power off for 10 seconds
at least, and then turn the power back for remote control learn function
setting.
Note: If the fan is installed with light, light will twinkle 2 times. The remote
control setting process is complete and your fan is ready for use. For fans
without light, check operation using remote transmitter.
Note: If you want to control the fan with another transmitter, make the same
setting. A fan can be controlled by 2 transmitters maximum.
The receiver provides the following protective functions
Lock protection- The DC motor has a build-in safety feature against blade or motor obstruction during operation. If
something obstructs the fan blades or motor, the motor will keep trying to run for 5 times and then stop operation
after about 60 seconds of interruption. Please remove obstacles and reset. To reset it by turn the fan off by remote
transmitter and then turn the fan on, Or you may turn power off for 15 seconds then turn power back, and then turn
the fan on,
Over load protection (current limit)- The device will limits the maximum current output from the receiver/drive when the
fan or light load was increased abnormally.
© 2020 Monte Carlo Fan Collections
Learn
6
Universal Mold
COMMON
COMMON
CODE
CODE
L.CODE
L.CODE
Learning Mold
1/2020