Heat source module
Heating output W10/W35 ΔT 5 K
Power consumption W10/W35 ΔT 5 K
Output figure W10/W35 ΔT 5 K/coefficient
of performance EN 14511
Heating output W10/W45 ΔT 5 K
Power consumption W10/W45 ΔT 5 K
Output figure W10/W45 ΔT 5 K/coefficient
of performance EN 14511
Heating output W10/W55 ΔT 8 K
Power consumption W10/W55 ΔT 8 K
Output figure W10/W55 ΔT 8 K/coefficient
of performance EN 14511
Sound power level W10/W35
EN 12102/EN 14511 L
in heating mode
WI
Sound power level W10/W45
EN 12102/EN 14511 L
in heating mode
WI
Sound power level W10/W55
EN 12102/EN 14511 L
in heating mode
WI
Application limits for the heat pump: Heating (heat source = groundwater)
At the same volume flow rates in the heating circuit (ΔT 5 K or ΔT 8 K) and the groundwater circuit (ΔT 3 K) as for the
nominal heat output test under standard nominal conditions. Operation of the pump outside the application limits results
in the heat pump being switched off by the internal control and safety devices.
Application limits for the heat pump: Heating (Groundwater heat source):
W15/W65
W25/W59
W25/W25
W10/W25
W10/W65
0020213394_01 flexoTHERM exclusive Installation and maintenance instructions
VWF 57/4
VWF 87/4
VWW 11/4 SI
VWW 11/4 SI
6.40 kW
10.00 kW
1.40 kW
1.90 kW
4.80
5.20
6.30 kW
10.10 kW
1.70 kW
2.50 kW
3.70
4.10
6.30 kW
10.30 kW
2.10 kW
3.00 kW
3.00
3.50
41.2 dB(A)
47.9 dB(A)
40.9 dB(A)
50.3 dB(A)
41.8 dB(A)
53.8 dB(A)
VWF 117/4
VWF 157/4
VWW 11/4 SI
VWW 19/4 SI
12.90 kW
16.80 kW
2.40 kW
3.10 kW
5.10
5.40
12.90 kW
16.60 kW
3.10 kW
4.00 kW
4.00
4.20
13.30 kW
17.10 kW
3.90 kW
4.80 kW
3.30
3.60
45.0 dB(A)
49.9 dB(A)
47.8 dB(A)
48.0 dB(A)
47.6 dB(A)
49.1 dB(A)
Appendix
VWF 197/4
VWW 19/4 SI
23.00 kW
4.40 kW
5.20
23.60 kW
5.60 kW
4.10
23.80 kW
6.80 kW
3.50
50.6 dB(A)
47.8 dB(A)
46.4 dB(A)