Removing And Replacing A Fan Canister; After Replacing A Fan Canister - Bosch E2800 Installation Manual

Table of Contents

Advertisement

46
en | Maintenance
8.3.2

Removing and replacing a fan canister

When you remove the failed fan canister, you do not have to turn off power to your storage
array. You must ensure that you remove and replace the fan canister within 30 minutes to
prevent the system from overheating.
To remove and replace a fan canister:
1.
2.
3.
4.
5.
8.3.3

After replacing a fan canister

After replacing a fan canister, you must confirm that the new fan canister is working correctly.
Then, you can gather support data and resume operations.
To confirm that the new fan-canister is working correctly:
1.
2.
2021.05 | V3 | DOC
1
Attention LED
Solid amber: The fan is faulty.
Put on antistatic protection.
Unpack the new fan canister, and place it on a level surface near the unit.
Save all packing material for use when returning the failed fan.
Press the orange release button to release the fan canister handle.
1 = Release button
Use the fan canister handle to pull the fan canister out of the unit.
1 = Fan canister handle
Slide the replacement fan canister all the way into the unit, and then move the fan
canister handle until it latches with the orange release button.
Check the amber Attention LED on the new fan canister.
Note: After you have replaced the fan canister, the Attention LED shows a steady amber
color while the firmware checks that the fan canister was installed correctly. The LED
goes off after this process is complete.
From the Recovery Guru in SANtricity System Manager, select Recheck to ensure the
problem has been resolved.