Connecting up

6.1

Safety when connecting up

Safety notices
When connecting up the device, keep to the safety notices listed below.
The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited
Power Source (LPS).
This means that only SELV / LPS complying with IEC 60950-1 / EN 60950-1 / VDE 0805-1
must be connected to the power supply terminals, or the power supply unit for the equipment
power supply must comply with NEC Class 2, as described by the National Electrical Code (r)
(ANSI / NFPA 70).
If the equipment is connected to a redundant power supply (two separate power supplies),
both must meet these requirements.
NOTICE
Failure of the data traffic due to contamination of optical plug-in connections
Optical sockets and plugs are sensitive to contamination of the end face. Contamination can
lead to the failure of the optical transmission network. Take the following precautions to avoid
functional impairments:
● Clean the end face of field-assembled connectors carefully before connecting. No residues
● Only remove the dust caps of optical transceivers and pre-configured cables shortly before
● Close unused optical sockets and plugs as well as pluggable transceivers and slots with
SCALANCE X-100
Operating Instructions, 02/2019, A2B00060666-10
WARNING
of processing may remain on the connector.
connecting the cables.
the supplied protective caps.