Technical specifications
Forwarding of PRP frames (Parallel
Redundancy Protocol)
PoE properties
PoE standard
Performance
Note
As of an ambient temperature of 55 °C, there must be a clearance of 40 mm to neighboring
devices on both sides.
Note
The number of SCALANCE X Industrial Ethernet switches connected in a line influences the
frame delay time.
When a frame passes through devices of the SCALANCE X-100 product line, it is delayed by
the store and forward function of the switch
● with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps)
● with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps)
This means that the more devices of the SCALANCE X-100 product line, the frame passes
through, the longer the frame delay.
Note
Temperature code for c-UL-us for hazardous locations, FM and ATEX Zone 2
You will find the temperature code "T.." or the maximum ambient temperature "Ta: .." on the
type plate.
8.5
SCALANCE X112-2
8.5.1
SCALANCE X112-2
Table 8-5
Technical specifications of the SCALANCE X112-1
Technical specifications
Order number
SCALANCE X112-2
Connection to Industrial Ethernet
Number
Design
Properties
Transmission speed
SCALANCE X-100
Operating Instructions, 02/2019, A2B00060666-10
Yes
802.3af
maximum
6GK5112-2BB00-2AA3
12
RJ-45 jacks with MDI‑X pinning
Half / full duplex
10/100 Mbps
Technical specifications
8.5 SCALANCE X112-2
15.4 W
53