Siemens SIMATIC NET SCALANCE X-100 Operating Instructions Manual page 48

Industrial ethernet switches
Table of Contents

Advertisement

Technical specifications
8.2 SCALANCE X106-1
Technical specifications
Aging time
Max. number of learnable MAC ad‐
dresses
Response to LLDP frames
Response to spanning tree BPDU
frames
CoS acc. to IEEE 802.1Q
QoS priority queues
Maximum frame size
Forwarding of PRP frames (Parallel
Redundancy Protocol)
Note
The number of SCALANCE X Industrial Ethernet switches connected in a line influences the
frame delay time.
When a frame passes through devices of the SCALANCE X-100 product line, it is delayed by
the store and forward function of the switch
● with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps)
● with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps)
This means that the more devices of the SCALANCE X-100 product line, the frame passes
through, the longer the frame delay.
Note
Temperature code for c-UL-us for hazardous locations, FM and ATEX Zone 2
You will find the temperature code "T.." or the maximum ambient temperature "Ta: .." on the
type plate.
Optical connectors
Quantity
Connectors
Properties
Transmission mode
Transmission rate
Transmission medium
Light source
48
30 seconds
2048
Blocking
Forwarding
Yes
4
1536 bytes
Yes
100Base-FX complying with IEEE 802.3
100 Mbps (Fast Ethernet)
Multimode fiber-optic cable
LED/Class1-LASER "Eye safe"
2
The attachment to Industrial Ethernet uses ST/
BFOC connector technology (Straight Tip/Bayo‐
net Fiber Optic Connector).
Operating Instructions, 02/2019, A2B00060666-10
SCALANCE X-100