Description of the device
4.2 Product overview
Device
SCALANCE X112-2
SCALANCE X116
SCALANCE X124
Unpacking and checking
Do not use any parts that show evidence of damage
If you use damaged parts, there is no guarantee that the device will function according to the
specification.
If you use damaged parts, this can lead to the following problems:
● Injury to persons
● Loss of the approvals
● Violation of the EMC regulations
● Damage to the device and other components
Use only undamaged parts.
1. Make sure that the package is complete.
2. Check all the parts for transport damage.
Components of the product
The following components are supplied with a SCALANCE X-100:
● IE Switch SCALANCE X-100
● 2-pin plug-in terminal block (signaling contact)
● 4-pin plug-in terminal block (power supply)
● Product information
Accessories
Component
IE FC Stripping Tool
IE FC blade cassettes (5 mm)
IE FC TP standard cable GP
IE FC TP trailing cable
IE FC TP marine cable
IE FC TP trailing cable GP
IE FC TP flexible cable GP
IE FC TP FRNC cable GP
14
Description
12x 10/100 Mbps RJ45 ports, 2x 100 Mbps
multimode BFOC
16x 10/100 Mbps RJ45 ports
24x 10/100 Mbps RJ45 ports
WARNING
Packaging unit
1
1
1
1
1
1
1
1
Article number
6GK5 112-2BB00-2AA3
6GK5 116-0BA00-2AA3
6GK5 124-0BA00-2AA3
Order number
6GK1901‑1GA00
6GK1901‑1GB01
6XV1840‑2AH10
6XV1840‑3AH10
6XV1840‑4AH10
6XV1870‑2D
6XV1870‑2B
6XV1871-2F