Technical specifications

8.6 SCALANCE X116

Optical connectors
Quantity
Connectors
Properties
Transmission mode
Transmission rate
Transmission medium
Light source
Wavelength
Cable length (max.) *
Transmitter output (optical)
Receiver input
*) Depending on the cable used:
● If you are using at least OM1 fibers (attenuation ≤ 1.5 dB/km, bandwidth length product ≥
500 MHz*km), you can reach a cable length of up to 3 km.
● When are using fibers with attenuation values ≤ 1 dB/km, you can reach a cable length of
up to 5 km.
You can find additional information in the "Industrial Ethernet / PROFINET Passive network
components" System Manual, see also section "Introduction", paragraph "Additional
documentation".
8.6
SCALANCE X116
Table 8-6
Technical specifications of the SCALANCE X116
Technical specifications
Order number
SCALANCE X116
Connection to Industrial Ethernet
Number
56
100Base-FX complying with IEEE 802.3
100 Mbps (Fast Ethernet)
Multimode fiber-optic cable
LED/Class1-LASER "Eye safe"
1300 nm
At 50 µm fiber core diameter
)
At 62.5 µm fiber core diameter
Minimum
Maximum
Sensitivity min.
Input power max.
6GK5116‑0BA00‑2AA3
16
2
The attachment to Industrial Ethernet uses ST/
BFOC connector technology (Straight Tip/Bayo‐
net Fiber Optic Connector).
At 50 μm
At 62.5 μm
Operating Instructions, 02/2019, A2B00060666-10
3 km
3 km
-23 dBm
-19 dBm
-14 dBm
-32 dBm
-3 dBm