Function Operation - STEINEL HF 3360-R COM1 UP WS Information

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 11
Note: The system cannot be switched OFF, it is only possible to select operation via
setting I or II.
a) Load, lighting max. 2000 W (refer to Technical specifications)
b) Sensor connection terminals
c) Indoor switch
d) Indoor two-circuit single-interruption switch, manual, automatic
e) Indoor two-way switch, automatic, light permanently ON
Connecting several sensors in parallel (not illustrated)
In this case, it is important not to exceed a sensor's maximum connected rating. In
addition, all units must be connected to the same phase. As many as 10 sensors can
be connected in parallel.
Note: The cable between two sensors must be no more than 50 m in length.
5. Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Select an appropriate mounting location, taking the reach and
motion detection into consideration.
Installation procedure
Wall-mounting, concealed power supply lead (Fig. 5.1)
Ceiling mounting, concealed power supply lead (Fig. 5.2)
Wall-mounting, surface-mounted power supply lead (Fig. 5.3)
Ceiling mounting, surface-mounted power supply lead (Fig. 5.4)
• Switch OFF power supply.
• Detach designer trim from sensor module.
• Disconnect sensor module from the load module.
• Connect to mains power supply.
- Surface-mounted power supply lead. (Fig. 5.5)
- Concealed power supply lead. (Fig. 5.6)
• Insert fastening screw and mount load module.
• Fit sensor and load module together and screw into place.
• Switch ON power supply.
• Set functions. (➔ "6. Function")
• Fit decorative trim panel.
22
6. Function / operation
Factory settings
Twilight level:
1000 lux
Reach adjustment:
approx. 1 m
Time setting:
5 s
Twilight setting (Fig. 6.1)
The chosen sensor response threshold is infinitely adjustable
from approx. 2 to 1000 lux.
Control dial
means twilight mode at approx. 2 lux.
Control dial
means daylight operation / independent of ambient light level.
Teach mode
The control must be set to
at the level of light at which you want the sensor to
respond to movement from now on. The level of ambient brightness measured in this
way will be saved after 10 seconds. Load is deactivated during this period.
Dazzle guard
This product is equipped with an integrated dazzle guard. If blinded by extraneous
light, this puts the sensor into a brightness-related evaluation mode for 60 s.
(➔ "11. Troubleshooting")
Presence detection switch-off logic
The load connected is switched OFF once the selected light level is exceeded.
Reach setting (Fig. 6.1)
Infinitely adjustable
– Control dial set to maximum = max. reach (approx. Ø 8 m)
– Control dial set to minimum = min. reach (approx. Ø 1 m)
Reach diagram (Fig. 6.2)
Time setting (Fig. 6.1)
The time you want the connected lamp to stay ON for is infinitely adjustable from
approx. 5 sec to a maximum of 15 min. Any movement detected before this time
elapses will restart the timer.
Pulse function
The pulse function activates the output for 2 s (e.g. for staircase lighting time switch-
es). The sensor will then be in a dead time for 8 seconds.
Note: is the pulse function is selected via the controller, time cannot be set by remote
control.
23