Endpoint Requirements
V-Series Software
All software versions are supported
VTX Software
VTX 1.30 software or greater
ViewStation Software
ViewStation, SP, SP384 6.0 software or greater
ViewStation FX/EX 5.0 software or greater
ViaVideo Software
ViaVideo 5.0 software or greater
iPower Software
iPower 5.0 software or greater
PathNavigator
PathNavigator version 1.0 or greater
MGC
MGC version 5.0 or greater
WebCommander
WebCommander Version 3.01 or greater
Network Requirements
Please note the following network connectivity requirements. Proxy servers, web-caches and firewalls
can prevent ReadiManager LX100 from operating correctly.
The ReadiManager LX100 server must have a direct IP connection to the managed device on
the following port:
ViewStation and V-Series: TCP port 80 (HTTP) and TCP port 21 and 24 (FTP)
o
ViaVideo: TCP port 3603
o
WebCommander: TCP port 80 (HTTP)
o
iPower: TCP port 80 (HTTP)
o
Other Devices on the port specified when the device is added. If these ports are blocked
o
by a firewall, cached or proxied, ReadiManager LX100 will not be able to manage the
systems.
The ViewStation, V Series, ViaVideo, or iPower must have direct IP access to the server on
TCP port 80 (HTTP) in order to post real-time status updates. If this port is blocked, cached
or proxied, ReadiManager LX100 will not receive status updates from the system – this will
prevent many features of ReadiManager LX100 from working correctly.
In order for the endpoints to register to the Global Directory, the following port on the firewall
must be opened:
ViewStation and V-Series: TCP on port 3601
o
iPower: TCP on port 3601
o
ViaVideo: TCP on port 3601
o
ReadiManager LX100