Ambient Temperature; Oil Temperature; Viscosity; Filtering - Danfoss H1B060 User Manual

Bent axis variable displacement motors
Table of Contents

Advertisement

User Manual
ATEX H1 Bent Axis Variable Displacement Motors
Technical information

Filtering

©
Danfoss | August 2021
W
Warning
It is compulsory to use oils whose inflammable degree is at least 50K above the maximum surface
temperature of the motors. See also .

Ambient temperature

Maximum ambient temperature depends on the requested ATEX class needed.
In general the ambient temperature should lie between -40° C [-40° F] and +70° C [158 °F] to ensure that
the shaft seal retains its sealing capacity.

Oil temperature

Maximum oil temperature depends on the requested ATEX class needed (in this case T3)..
Under normal operating conditions it is recommended to keep the temperature in the range of 60 °C
[140 °F] to 85 °C [185 °F].

Viscosity

Maintain fluid viscosity within the recommended range for maximum efficiency and bearing life.
Minimum viscosity should only occur during brief occasions of maximum ambient temperature and
severe duty cycle operation. Maximum viscosity should only occur at cold start. Limit speeds until the
system warms up.
Fluid viscosity limits
Conditions
Minimum
Continuous
Maximum
We recommend the use of an oil type having a viscosity of 12 - 80mm
operating temperature.
It is necessary to keep the level of oil contamination at an acceptable level to ensure problem-free
operation. The recommended maximum level of contamination in systems in the hydraulic motors is
22/20/16 (ISO 4406-1999).
2
mm
/s (cSt)
5
7
1600
SUS
42
49
7416
2
/s [66 - 371 SUS] at the actual
BC382476021584en-000102 | 9