required to enter the Proxy Server if it was the same as the Registrar
Server; however, in version 8.0.2 you are required to enter an address in
both fields in order to register to the server.
If you register to a SIP server on the Setup > SIP page, unregister, and then
place a SIP call, the far site will display your IP address as unreadable
characters. To correct this issue, restart the system after changing SIP
server settings.
SIP calls to systems using MSN Windows Messenger or Microsoft Office
Communicator may:
— Report incorrect calling rates on the PVX Media Statistics page.
— Connect with audio only.
— Connect at line rates lower than those requested when the call was
dialed.
— Fail to resume video transmission if the Pause feature on
Communicator is activated.
PVX SIP calls to a VSX version 7.5.2 may intermittently fail to connect.
Redialing the call or upgrading the VSX to version 8.x will correct the
problem.
If two PVX endpoints with identical user names both register to the same
Microsoft LCS server, the second user to register will be able to answer
incoming PVX SIP calls from a third system. The first to register will not.
PVX systems located behind a Cisco PIX® firewall will be unable to
receive incoming SIP calls routed through a Microsoft LCS server.
Nortel MCS Servers will confirm registration of a PVX system even if a
blank or incorrect server password is used.
Nortel MCS servers do not support PVX SIP calls that use a ViaVideo
camera.
PVX SIP calls through an SMC SMC7004BR NAT firewall device will
transmit an incorrect IP address to a far-site system. If the far-site system
saves that information in the address book and attempts to place a return
call using the saved entry, the call will not connect.
If a PVX system that is registered to a Microsoft LCS server does not
answer an incoming SIP call, the call cannot be returned using the address
as listed in the Recent Call log.
User Interface
In this version of PVX, you must enter the access password on both the
Page Access page and the Feature Access page.
To display help on using the menu tree in the PVX Setup screens, click the
? Button in the upper left corner of the screen and then click the menu tree.
Displaying help by right-clicking the menu tree is not supported.
The help topic which describes the setup pages incorrectly implies that the
user can set the default SIP port.