Programming Special Functions - Miele G 7856 Operating Instructions Manual

Commercial dishwasher
Table of Contents

Advertisement

For future servicing work, please
document any alterations to the stan-
dard factory settings.
Enter any alterations in the relevant
Value set:_________ box.
1. Setting the cold water inlet from:
Nominal water intake to Nominal wa-
ter intake + 1 l.
The amount of water taken into the
machine at each intake can be
increased by 1 litre to a maximum of
9.5 litres.
To do this:
^ Turn the programme selector to STOP
f.
^ Switch the machine off.
^ Press and hold 4 and 6 at the
same time, and whilst doing so
switch the machine on with the I-0
button.
The current programme status "P..."
appears in the display and the p / 6
indicator lights up.
^ Press 3 once. E01 for programming
level 1 will appear in the display.
^ Turn the programme selector to the
D position. A 10 or an 11 will appear
in the display.
10 = Nominal water intake
11 = Nominal water intake + 1 l
^ Press 4 to change from 10 to 11 or
vice versa.
^ Press 6. SP appears.
^ Press 6 again. The change has
been recorded.

Programming special functions

Value set:
2. Selecting a second interim rinse
"Interim rinse II" can be programmed in
.
to improve interim rinsing in all
programmes (with the exception ofD
PRE-RINSE and J SUPER SHORT).
^ Turn the programme selector to STOP
f.
^ Switch the machine off.
^ Press and hold 4 and 6 at the
same time, and whilst doing so
switch the machine on with the I-0
button.
The current programme status "P..."
appears in the display and the p / 6
indicator lights up.
^ Press 3 once. E01 for programming
level 1 will appear in the display.
^ Turn the programme selector to o. A
30 or an 31 will appear in the display.
30 = without Interim rinse II.
31 = with Interim rinse II.
^ Press 4 to change from 30 to 31 or
vice versa.
^ Press 6. SP appears.
^ Press 6 again. The change has
been recorded.
Value set:
33