CONTROL PANEL

1. Terminal Block: used for external accessories (see chart below).
Ref Function
Push button
A
Common
B
B Common
C
Obstruction Detection
Beams
Accessory Power
D
NOTE: The terminal block is behind a plastic cover in the back housing. Use a small screwdriver to lever
open the plastic cover if access to the terminal block is required. All wires should be secured appropriately.
2. DN Button: used to drive the door DOWN
3. UP Button: used to drive the door UP
4. P Button: used to "PROGRAM" the DOOR LIMITS (see section 14)
5. S Button: used to "SAVE" and "DELETE" the "REMOTE CONTROLS" (see section 21)
6. LEDs: 1. Program DOWN, and Diagnostic code indicator Number 1
D
2. Program UP indicator
C
B
3. Diagnostic code indicator Number 2
B
A
1
7. Control Button: Used to activate the door when remote controls are not available. Open - Stop - Close.
8. Courtesy Light: turns on during operation and automatically turns off after a period of 3 minutes
D
C
B
B
A
1
Colour Polarity Comment
Red
+ve
White
-ve
White
-ve
Grey
+ve
Green
+ve
8
DN
6
8
DN
6
Dry contact input for push button wired wall
controls
Common terminal for push button, obstruction
detection beams & accessory power
Common terminal for push button, obstruction
detection beam & accessory power
Obstruction detection beam input (pulsing
type only) - see section 18
24v dc 50 mA accessory output available for a
universal receiver (output not active in Standby Mode)
2
3
4
1
2
UP
P
2
3
4
1
2
UP
P
3
5
3
S
6
7
5
3
S
6
7