MS65MYQ
Sectional Garage Door Opener
Installation and Operating Instructions
Owners Copy: SAVE THESE INSTRUCTIONS for future reference
This manual contains IMPORTANT SAFETY information
DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY

Advertisement

Table of Contents
loading

Summary of Contents for Merlin MS65MYQ

  • Page 1 Commander Essential MS65MYQ Sectional Garage Door Opener Installation and Operating Instructions Owners Copy: SAVE THESE INSTRUCTIONS for future reference This manual contains IMPORTANT SAFETY information DO NOT PROCEED WITH THE INSTALLATION BEFORE READING THOROUGHLY...
  • Page 2: Table Of Contents

    400 N (40 kgf). Excessive force will interfere with before installing this opener. the proper operation of the Safety Reverse System or damage SPECIAL NOTE: Merlin strongly recommends that The the garage door. Do not wear rings, watches or loose clothing while Protector System be installed on all garage door openers.
  • Page 3: Before You Begin

    BEFORE YOU BEGIN: 1. Look at the wall and ceiling above the garage door. (The opener and header bracket must be securely fastened to structural supports). 2. Do you have a finished ceiling in your garage? If so, a support bracket and additional fastening hardware (not supplied) may be required.
  • Page 4: Carton Inventory

    CARTON INVENTORY Your garage door opener and rail are packed in two seperate cartons. The Commander Essential MS65MYQ opener carton contains the opener, its fitting hardware and accessories. The rail carton contains the rail and some hardware. Rails: Different length rails (2.2 m & 2.4 m) are available for different height doors, ensure you have the correct one.
  • Page 5: Tools Required

    TOOLS REQUIRED Drill Bits HARDWARE PROVIDED (1) Clevis pin 80 mm (Section 12) (2) R clip (Section 12) (3) Hexagonal head screw (Sections 14 & 16) 1 (1x) 2 (1x) 3 (4x) (4) Nut M8 (Sections 14 & 16) 4 (4x) 5 (4x) (5) Flat washer M8 (Sections 14 &...
  • Page 6: Control Panel

    Common terminal for push button Common terminal for The Protector System™ (IR Beams) Ground White IR Sensor Grey Merlin IR Beam Input: (pulsing type only) Door-in-door Green For Door in Door dry contact sensor: (see note below) 30 V DC Door-in-door Green Common terminal for Door in Door sensor (4 &...
  • Page 7: Assembly

    ASSEMBLY SECTION Note: The spring must be able to compress and bounce TIGHTEN THE BELT 36 - 38 mm during operation. Final tensioning can be performed after installation if necessary. Over tightening the belt may overload the system and cause excessive wear. 1.Tension the belt by adjusting the nut (1), on the pulley assembly, clockwise until the spring is engaged.
  • Page 8: Installation

    INSTALLATION SECTION Wear protective goggles when working overhead to protect your eyes from injury. Disengage all existing garage door locks to avoid damage to the garage door. To avoid serious personal injury from entanglement, remove all ropes connected to the garage door before installing the opener.
  • Page 9 POSITION THE OPENER Disengage the trolley mechanism (see section “Operating the manual release”) and slide it back towards the powerhead. Secure the hanging push arm up into the rail assembly temporarily using tape or rope, to avoid a hazard. SECTIONAL DOOR You will need a 50 mm piece of timber or similar spacer to gauge the distance between door and rail.
  • Page 10 HANG THE OPENER The opener must be securely fastened to a sound structural support above the opener. fig.1 1.Postion the opener as in the previous step. Check the rail is centred over the door. Ensure the rail brackets (fig.1) is on the Powerhead end of the rail in a position as close to the opener as possible (X).
  • Page 11: Operate The Manual Release

    Make sure the garage door is fully closed. Pull the manual release ATTACH DOOR ARM TO TROLLEY cord to disengage the trolley. Slide the trolley to around 300 mm from Fig. 1 Fig. 2 the header bracket. 1.The straight door arm is already preassembled to the trolley. 2.Install the curved arm onto the door bracket using the Clevis pin (2) (item 6 in the Hardware Provided - Section 5) and R-Clip.
  • Page 12: Adjustment

    ADJUSTMENT SECTION Travel limits regulate the points at which the door will stop PROGRAM THE TRAVEL LIMITS AND FORCE SETTINGS Without a properly installed safety reversal when moving UP or DOWN. The travel limit buttons are located system, persons (particularly small children) under the access cover on the rear panel (figure 1).
  • Page 13 TEST THE SAFETY REVERSE SYSTEM The safety reverse system test is important. Garage door must reverse on contact with a 40 mm obstacle laid flat on the floor. Failure to properly adjust opener may result in serious personal injury from a closing garage door.
  • Page 14: Program Transmitter To Operate Opener Light

    (refer to paragraph 4 of the troubleshooting section). SAFETY FIRST! Whilst Merlin have engineered safety features into your garage door opener, we urge you to consider fitting The Protector ™ System (IR Beams) to your new garage door opener. In many countries these devices are compulsory to assist in preventing serious injury or property damage.
  • Page 15: Button

    TIMER TO CLOSE FEATURE (TTC) Door may operate unexpectedly, therefore do not allow anything to stay in the path of the door. figure 1 The Timer to Close feature requires The Protector System (IR Beams) to be installed. Indicator LED Operation: Door Fully Closed This feature allows the door to automatically close from a fully...
  • Page 16: Install Warning Labels

    INSTALL WARNING LABELS figure 1 For Service Call RISK OF ENTRAPMENT Installation Date Repeat Safety Reverse Test monthly. Door 114A3361 must reverse on contact with a 40mm obstacle For Service Call placed on the floor. Make necessary adjustments. AUTOMATIC DRIVE: Keep away from the area of the door since it may operate unexpectedly.
  • Page 17: Wireless Programming

    WIRELESS PROGRAMMING (OPTIONAL ACCESSORIES) Activate the opener only when door is in full view, free of obstruction and properly adjusted. No one should enter or leave garage while door is in motion. Do not allow children to operate push button(s) or remote(s). Do not allow children to play near the door.
  • Page 18: Using Your Opener

    MAINTENANCE AND CARE OF YOUR OPENER Battery of the remote control: USING YOUR OPENER REPLACE BATTERIES IN REMOTES 1. Your opener can be activated by any of the following devices: • Opener control panel: Up and Down Buttons and Green O.S.C. The batteries in the remote have an extremely long life.
  • Page 19: Accessories

    E1702M 760E 774ANZ 827AU NOTE: Use of any Chamberlain Group accessories are approved to use with this opener. This includes genuine Merlin accessories. Generic compatible accessories are NOT approved for use with this opener RAIL HARDWARE 002A1800 Trolley with rope &...
  • Page 20: Replacement Parts

    REPLACEMENT PARTS If the supply cord is damaged, it must be Power Cord replaced by the manufacturer, its service 026B0181 agent or similarly qualified persons in order to avoid hazard. 041A0005 Logic Board / PCB Housing / Control Cover (assembly) 041A4004 Passpoint Assembly...
  • Page 21: Troubleshooting

    TROUBLE SHOOTING 1. Opener doesn't operate from either door control or 7. Door opens but won't close: remote: • Check The Protector System™ (if you have installed • Does the opener have electric power? Plug lamp into this accessory). If the light on The Protector System™ outlet.
  • Page 22 DIAGNOSTIC CHART Your garage door opener is programmed with self-diagnostic capabilities. The UP and DOWN arrows on the garage opener flash the diagnostic codes. DIAGNOSTIC CODE SYMPTOM POSSIBLE RESOLUTION UP Arrow DOWN Arrow Flash(es) Flash(es) The garage door opener will not Safety sensors are not installed, connected or wires may be cut.
  • Page 23: Specifications

    SPECIFICATIONS - COMMANDER ESSENTIAL - MS65MYQ Input Voltage......220-240 Vac, 50 - 60 Hz. Max. Pull Force ......600 N. Power ........150 Watt. Standby Power ......0.8 Watt (door fully closed). Normal Torque ......5 Nm. Max door weight......90 kg. Max lift under spring tension ..20 kg.
  • Page 24: Warranty

    Chamberlain warrants to the original purchaser of the Merlin Commander 5 problems with, or relating to, the garage door or garage door hardware, Essential MS65MYQ Sectional Door Opener (Unit) that all parts of the Unit, including but not limited to the door springs, door rollers, door other than remote controlled transmitters and accessories, globes and alignment or hinges;...