Appendix A
Specifications
Physical
Dimensions
Maximum cable length
Slot requirements
Compatibility
Weight
Power Requirements
Power Rail
+3.3 V
+5 V
+12 V
+5 VAux
-12 V
Environment
Maximum altitude
Pollution Degree
Indoor use only.
Operating Environment
Ambient temperature range
Operating relative humidity
A-32 | ni.com
10.0 cm × 16.0 cm (3.9 in. × 6.3 in.)
7 m
One PXI Express system slot
Fully compatible with the PXI-5 Express
Hardware Specification, Revision 1.0
0.17 kg (0.37 lb) typical
Typical Current
2.5 A
10 µA
750 µA
0.3 A
0 A
2,000 m
2
0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2. Meets MIL-PRF-28800F
Class 3 low temperature limit and
MIL-PRF-28800F Class 2 high temperature
limit.)
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Maximum Current
3 A
3 mA
1 mA
0.4 A
0 A