National Instruments PCI-8361 User Manual page 101

Table of Contents

Advertisement

Weight
Power Requirements
Power Rail
+3.3 V
+5 V
+12 V
-12 V
VIO
Environment
Maximum altitude
Pollution Degree
Indoor use only.
Operating Environment
Ambient temperature range
Operating relative humidity
Storage Environment
Ambient temperature range
Relative humidity range
Shock and Vibration
Operational shock
0.15 kg (0.34 lb) typical
Typical Current
555 mA
8 mA
10 mA
0 A
0 A
2,000 m
2
0 to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
10 to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
-40 to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
5 to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27.
© National Instruments Corporation | B-17
MXI-Express x1 Series User Manual
Maximum Current
850 mA
10 mA
12 mA
0 A
1 mA