Summary of Contents for National Instruments IMAQ PCI-1407
Page 1
(217) 352-9330 | Click HERE Find the National Instruments IMAQ PCI-1407 at our website:...
Page 2
IMAQ ™ ™ IMAQ PCI/PXI -1407 User Manual High-Quality Monochrome Image Acquisition Boards for PCI, PXI, and CompactPCI Bus IMAQ PCI/PXI-1407 User Manual December 1998 Edition Part Number 322156A-01...
Page 4
Important Information Warranty The IMAQ PCI-1407 and PXI-1407 are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor.
Page 5
This device complies with the FCC rules only if used with shielded interface cables of suitable quality and construction. National Instruments used such cables to test this device and provides them for sale to the user. The use of inferior or nonshielded interface cables could void the user’s authority to operate the equipment under the...
About Your PCI/PXI-1407 ....................1-1 Using PXI with CompactPCI..................1-2 What You Need to Get Started ..................1-2 Software Programming Choices ..................1-3 National Instruments Application Software ............1-3 NI-IMAQ Driver Software ................1-4 Optional Equipment .......................1-6 Unpacking ........................1-6 How to Set up Your IMAQ System................1-6...
PXI-1407. • Appendix B, Customer Communication, contains forms you can use to request help from National Instruments or to comment on our products and manuals. • Glossary contains an alphabetical list and description of terms used in this manual, including abbreviations, acronyms, metric prefixes, mnemonics, and symbols.
• Software documentation—You may have both application software and NI-IMAQ software documentation. National Instruments application software includes LabVIEW and LabWindows/CVI. After you set up your hardware system, use either the application software (LabVIEW or LabWindows/CVI) documentation, or the NI-IMAQ documentation to help you write your application.
PCI Local Bus Specification, Revision 2.1 Customer Communication National Instruments wants to receive your comments on our products and manuals. We are interested in the applications you develop with our products, and we want to help if you have problems with them.
Introduction This chapter describes the IMAQ PCI-1407 and PXI-1407 devices; lists what you need to get started; describes software programming choices, optional equipment, and custom cables; and explains how to unpack and set up your PCI/PXI-1407. About Your PCI/PXI-1407 The PCI-1407 and PXI-1407 are high-accuracy, monochrome IMAQ boards for PCI, PXI, or CompactPCI chassis that support RS-170 and CCIR video standards.
PCI interface chipset. Software Programming Choices You have several options to choose from when programming your National Instruments IMAQ hardware. You can use National Instruments application software such as LabVIEW, BridgeVIEW, and LabWindows/CVI; National Instruments image analysis software such as IMAQ Vision; the ComponentWorks IMAQ Vision collection of ActiveX controls;...
The NI-IMAQ software does not perform any image analysis. For image analysis functionality, refer to the National Instruments Application Software section earlier in this chapter. NI-IMAQ has both high-level and low-level functions for maximum flexibility and performance.
Chapter 1 Introduction Any platform that supports NI-IMAQ also supports NI-DAQ and a variety of National Instruments DAQ boards, so your PCI/PXI-1407 and NI-IMAQ development can integrate with National Instruments DAQ products. Whether you are using conventional programming languages or National Instruments software, your application uses the NI-IMAQ driver software, as illustrated in Figure 1-1.
Chapter 1 Introduction Optional Equipment National Instruments offers a variety of products for use with your PCI/PXI-1407, including other National Instruments DAQ devices for enhanced triggering, timing, or input/output. For more specific information about these products, refer to your National Instruments catalogue or web site, or call the office nearest you.
Electronic Services Bulletin Board Support National Instruments has BBS and FTP sites dedicated for 24-hour support with a collection of files and documents to answer most common customer questions. From these sites, you can also download the latest instrument drivers, updates, and example programs. For recorded instructions on how to use the bulletin board and FTP services and for BBS automated information, call 512 795 6990.
Page 33
Telephone and Fax Support National Instruments has branch offices all over the world. Use the list below to find the technical support number for your country. If there is no National Instruments office in your country, contact the source from which you purchased your software to obtain support.
Page 34
National Instruments for technical support helps our applications engineers answer your questions more efficiently. If you are using any National Instruments hardware or software products related to this problem, include the configuration forms from their user manuals. Include additional pages if necessary.
Page 35
Complete a new copy of this form each time you revise your software or hardware configuration, and use this form as a reference for your current configuration. Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions more efficiently.
Page 36
Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: IMAQ PCI/PXI-1407 User Manual Edition Date: December 1998 Part Number: 322156A-01 Please comment on the completeness, clarity, and organization of the manual.
Page 44
NI-IMAQ driver software for National Instruments IMAQ hardware noninterlaced a video frame where all the lines are scanned sequentially, instead of divided into two frames as in an interlaced video frame NVRAM nonvolatile RAM—RAM that is not erased when a device loses power or...
Page 46
Also called a grounded measurement system. RTSI bus Real-Time System Integration Bus—the National Instruments timing bus that connects IMAQ and DAQ boards directly, by means of connectors on top of the boards, for precise synchronization of functions...
DMA controllers, 3-3 acquisition modes, 3-7 documentation acquisition window conventions used in manual, viii controlling, 3-4 to 3-6 National Instruments documentation, viii programming video parameters, 3-6 organization of manual, vi active line region, 3-5 related documentation, ix active pixel region, 3-5...
Page 49
See documentation. gain and offset circuitry, 3-2 genlock synchronization generator, 3-3 PCI interface, 3-4 pixel aspect ratio circuitry, 3-3 National Instruments application software, scatter-gather DMA controllers, 3-3 to 3-4 1-3 to 1-4 trigger control, 3-4 NI-IMAQ driver software, 1-4 to 1-5...