National Instruments IMAQ PCI-1407 User Manual

National Instruments IMAQ PCI-1407 User Manual

High-quality monochrome image acquisition boards for pci, pxi, and compactpci bus
Hide thumbs Also See for IMAQ PCI-1407:

Advertisement

Quick Links

sales@artisantg.com
artisantg.com
(217) 352-9330 |
|
Click HERE
Find the National Instruments IMAQ PCI-1407 at our website:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IMAQ PCI-1407 and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments IMAQ PCI-1407

  • Page 1 (217) 352-9330 | Click HERE Find the National Instruments IMAQ PCI-1407 at our website:...
  • Page 2 IMAQ ™ ™ IMAQ PCI/PXI -1407 User Manual High-Quality Monochrome Image Acquisition Boards for PCI, PXI, and CompactPCI Bus IMAQ PCI/PXI-1407 User Manual December 1998 Edition Part Number 322156A-01...
  • Page 3 Singapore 2265886, Spain 91 640 0085, Sweden 08 730 49 70, Switzerland 056 200 51 51, Taiwan 02 377 1200, United Kingdom 01635 523545 National Instruments Corporate Headquarters 6504 Bridge Point Parkway Austin, Texas 78730-5039 USA Tel: 512 794 0100 © Copyright 1998 National Instruments Corporation. All rights reserved.
  • Page 4 Important Information Warranty The IMAQ PCI-1407 and PXI-1407 are warranted against defects in materials and workmanship for a period of one year from the date of shipment, as evidenced by receipts or other documentation. National Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. This warranty includes parts and labor.
  • Page 5 This device complies with the FCC rules only if used with shielded interface cables of suitable quality and construction. National Instruments used such cables to test this device and provides them for sale to the user. The use of inferior or nonshielded interface cables could void the user’s authority to operate the equipment under the...
  • Page 6: Table Of Contents

    About Your PCI/PXI-1407 ....................1-1 Using PXI with CompactPCI..................1-2 What You Need to Get Started ..................1-2 Software Programming Choices ..................1-3 National Instruments Application Software ............1-3 NI-IMAQ Driver Software ................1-4 Optional Equipment .......................1-6 Unpacking ........................1-6 How to Set up Your IMAQ System................1-6...
  • Page 7 Figure 3-1. PCI/PXI-1407 Block Diagram .............. 3-2 Figure 3-2. Positive Video Line................3-5 Figure 3-3. Video Field.................... 3-6 Figure 4-1. PCI/PXI-1407 BNC I/O Connectors............. 4-1 Tables Table 4-1. I/O Connector Signals ................4-2 IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 8: About This Manual

    PXI-1407. • Appendix B, Customer Communication, contains forms you can use to request help from National Instruments or to comment on our products and manuals. • Glossary contains an alphabetical list and description of terms used in this manual, including abbreviations, acronyms, metric prefixes, mnemonics, and symbols.
  • Page 9: Conventions Used In This Manual

    • Software documentation—You may have both application software and NI-IMAQ software documentation. National Instruments application software includes LabVIEW and LabWindows/CVI. After you set up your hardware system, use either the application software (LabVIEW or LabWindows/CVI) documentation, or the NI-IMAQ documentation to help you write your application.
  • Page 10: Related Documentation

    PCI Local Bus Specification, Revision 2.1 Customer Communication National Instruments wants to receive your comments on our products and manuals. We are interested in the applications you develop with our products, and we want to help if you have problems with them.
  • Page 11: Introduction

    Introduction This chapter describes the IMAQ PCI-1407 and PXI-1407 devices; lists what you need to get started; describes software programming choices, optional equipment, and custom cables; and explains how to unpack and set up your PCI/PXI-1407. About Your PCI/PXI-1407 The PCI-1407 and PXI-1407 are high-accuracy, monochrome IMAQ boards for PCI, PXI, or CompactPCI chassis that support RS-170 and CCIR video standards.
  • Page 12: Using Pxi With Compactpci

    NI-IMAQ for Windows 95/98/NT and online documentation Optional software packages and documentation: – LabVIEW – BridgeVIEW – LabWindows/CVI – IMAQ Vision for G – IMAQ Vision for LabWindows/CVI – ComponentWorks IMAQ Vision IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 13: Software Programming Choices

    PCI interface chipset. Software Programming Choices You have several options to choose from when programming your National Instruments IMAQ hardware. You can use National Instruments application software such as LabVIEW, BridgeVIEW, and LabWindows/CVI; National Instruments image analysis software such as IMAQ Vision; the ComponentWorks IMAQ Vision collection of ActiveX controls;...
  • Page 14: Ni-Imaq Driver Software

    The NI-IMAQ software does not perform any image analysis. For image analysis functionality, refer to the National Instruments Application Software section earlier in this chapter. NI-IMAQ has both high-level and low-level functions for maximum flexibility and performance.
  • Page 15: Figure 1-1. The Relationship Between The Programming Environment

    Chapter 1 Introduction Any platform that supports NI-IMAQ also supports NI-DAQ and a variety of National Instruments DAQ boards, so your PCI/PXI-1407 and NI-IMAQ development can integrate with National Instruments DAQ products. Whether you are using conventional programming languages or National Instruments software, your application uses the NI-IMAQ driver software, as illustrated in Figure 1-1.
  • Page 16: Optional Equipment

    Chapter 1 Introduction Optional Equipment National Instruments offers a variety of products for use with your PCI/PXI-1407, including other National Instruments DAQ devices for enhanced triggering, timing, or input/output. For more specific information about these products, refer to your National Instruments catalogue or web site, or call the office nearest you.
  • Page 17: Figure 1-2. How To Set Up Your Imaq System

    NI-IMAQ functions. If you are using IMAQ Vision for LabWindows/CVI, read the documentation for IMAQ Vision for LabWindows/CVI. Figure 1-2. How to Set up Your IMAQ System © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 18: Installation

    Slowly push down on the top of the PCI-1407 until its card-edge connector is resting on the expansion slot receptacle. Using slow, evenly distributed pressure, press the PCI-1407 straight down until it seats in the expansion slot. © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 19 Screw the front panel of the PXI-1407 to the front panel mounting rails of the PXI or CompactPCI chassis. Visually verify the installation. Plug in and turn on the PXI or CompactPCI chassis. Your PXI-1407 is now installed. IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 20: Hardware Overview

    PCI bus. The board also includes a trigger for controlling the image acquisition. The block diagram in Figure 3-1 illustrates the key functional components of the PCI-1407 and PXI-1407. © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 21: Video Buffer

    An 8-bit flash ADC digitizes the image, which is passed to a 256-by-8 bit lookup table (LUT) RAM. You can configure the input LUT to implement simple imaging operations such as contrast enhancement, data inversion, gamma manipulation, or other nonlinear transfer functions. IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 22: Csync Mux

    The PCI/PXI-1407 uses three independent onboard direct memory access (DMA) controllers. The DMA controllers transfer data between the onboard first-in first-out (FIFO) memory buffers and the PCI bus. Each of these controllers supports scatter-gather DMA, which allows the DMA © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 23: Pci Interface

    • Delayed acquisition—You can use either software or the trigger to start and stop acquisitions instantaneously or after capturing a desired number of frames or fields. Use this feature for trigger applications. IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 24: Acquisition Window Control

    Pixel aspect ratio—The pixel aspect ratio is the ratio between the physical horizontal size and the vertical size of the region covered by the pixel. An acquired pixel should optimally be square, thus the © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 25: Programming Video Parameters

    When you disable the region-of-interest circuitry, the board stores the entire acquisition window in system memory. However, when you enable the IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 26: Acquisition Modes

    PCI/PXI-1407 receives an incoming video signal (composite or luminance) and an external CSYNC signal from an external connector. The PCI/PXI-1407 takes the incoming CSYNC signal and generates HSYNC, VSYNC, and PCLK signals. © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 27: Signal Connections

    PCI/PXI-1407 VIDEO, CSYNC and TRIG inputs. Use BNC cables to connect a camera to these inputs. You can configure the BNC connector only for referenced single-ended (RSE) mode. VIDEO CSYNC TRIG Figure 4-1. PCI/PXI-1407 BNC I/O Connectors © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 28: I/O Connector Signal Connection Descriptions

    You can also program the triggers to be programmatically asserted or unasserted similar to the function of a digital I/O line or to contain internal status signals (by using the onboard events) or specific pulse widths. IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 29: Appendix A Specifications

    White reference ........Programmable (0–1.26 V) A/D Conversion Gray levels ..........256 (8 bit) RMS noise..........< 0.5 LSB rms Signal-to-noise ratio....... 48 dB typ Sampling rate ......... 5 to 20 MHz © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 30 Card type..........32-bit half-size card Parity generation/checking, error reporting.........Supported Target decode speed .......Medium (1 clock) Target fast back-to-back capability ..Supported Resource locking ........Supported as a master and slave PCI interrupts..........Interrupts passed on INTA# signal IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 31 –12 V (50 mA) Physical Dimensions PCI-1407 ......... 10.668 by 17.463 cm (4.2 by 6.875 in.) PXI-1407......... 16 × 10 cm (6.3 × 3.9 in.) Weight PCI-1407 ......... 0.127 kg (0.028 lb.) © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 32: Appendix B Customer Communication

    Electronic Services Bulletin Board Support National Instruments has BBS and FTP sites dedicated for 24-hour support with a collection of files and documents to answer most common customer questions. From these sites, you can also download the latest instrument drivers, updates, and example programs. For recorded instructions on how to use the bulletin board and FTP services and for BBS automated information, call 512 795 6990.
  • Page 33 Telephone and Fax Support National Instruments has branch offices all over the world. Use the list below to find the technical support number for your country. If there is no National Instruments office in your country, contact the source from which you purchased your software to obtain support.
  • Page 34 National Instruments for technical support helps our applications engineers answer your questions more efficiently. If you are using any National Instruments hardware or software products related to this problem, include the configuration forms from their user manuals. Include additional pages if necessary.
  • Page 35 Complete a new copy of this form each time you revise your software or hardware configuration, and use this form as a reference for your current configuration. Completing this form accurately before contacting National Instruments for technical support helps our applications engineers answer your questions more efficiently.
  • Page 36 Documentation Comment Form National Instruments encourages you to comment on the documentation supplied with our products. This information helps us provide quality products to meet your needs. Title: IMAQ PCI/PXI-1407 User Manual Edition Date: December 1998 Part Number: 322156A-01 Please comment on the completeness, clarity, and organization of the manual.
  • Page 37: Glossary

    (relative to VSYNC) and a line count © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 38 See also white reference level. IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 39 © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 40 A/D conversion IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 41 © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 42 Basic, C or Pascal, by reading one line at a time and executing the specified operation See also compiler. IMAQ PCI/PXI-1407 User Manual © National Instruments Corporation...
  • Page 43 IMAQ Configuration Utility that contains formulas that let you implement simple imaging operations such as contrast enhancement, data inversion, gamma manipulation, or other nonlinear transfer functions © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 44 NI-IMAQ driver software for National Instruments IMAQ hardware noninterlaced a video frame where all the lines are scanned sequentially, instead of divided into two frames as in an interlaced video frame NVRAM nonvolatile RAM—RAM that is not erased when a device loses power or...
  • Page 45 © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...
  • Page 46 Also called a grounded measurement system. RTSI bus Real-Time System Integration Bus—the National Instruments timing bus that connects IMAQ and DAQ boards directly, by means of connectors on top of the boards, for precise synchronization of functions...
  • Page 47 See also black reference level. © National Instruments Corporation G-11 IMAQ PCI/PXI-1407 User Manual...
  • Page 48: Index

    DMA controllers, 3-3 acquisition modes, 3-7 documentation acquisition window conventions used in manual, viii controlling, 3-4 to 3-6 National Instruments documentation, viii programming video parameters, 3-6 organization of manual, vi active line region, 3-5 related documentation, ix active pixel region, 3-5...
  • Page 49 See documentation. gain and offset circuitry, 3-2 genlock synchronization generator, 3-3 PCI interface, 3-4 pixel aspect ratio circuitry, 3-3 National Instruments application software, scatter-gather DMA controllers, 3-3 to 3-4 1-3 to 1-4 trigger control, 3-4 NI-IMAQ driver software, 1-4 to 1-5...
  • Page 50 VIDEO signal (table), 4-2 NI-IMAQ driver software, 1-4 to 1-5 VSYNC specifications, A-1 to A-4 acquisition window control, 3-5 A/D conversion, A-1 genlock synchronization generator, 3-3 environment, A-3 to A-4 external connections, A-2 © National Instruments Corporation IMAQ PCI/PXI-1407 User Manual...

This manual is also suitable for:

Imaq pxi-1407

Table of Contents