A-5
INSTALLATION
CABLE CONNECTIONS
See FIGURE A.2 for locating 6-pin and 14-pin con-
nectors on the front of the FLEXTEC™ 450 CE.
6-PIN REMOTE CONTROL CONNECTOR
Function
Pin
6-pin remote
A
77 Remote potentiometer, 5K
control con-
76 Remote potentiometer, wiper
B
nector for
C
75 Remote potentiometer, common
remote or
D
Trigger, common
hand/foot
E
Trigger, input
amptrol.
F
Ground
14-PIN CONNECTOR FOR WIRE FEEDER
Function
Pin
14 pin con-
A
nector for
B
Ground
wire feeder
C
Trigger, Common
connectivity.
D
Trigger input
E
77 Remote potentiometer, 5K
76 Remote potentiometer, wiper
F
G
75 Remote potentiometer, common
H
Voltage Sense (21)
I
Motor (42 VAC)
J
Motor (42 VAC)
K
L
M
N
FIGURE A.2
FLEXTEC™ 450 CE
Wiring
Wiring
A-5