Network; Network Services; Network Access - Bosch NDE-8503-R User Manual

Hide thumbs Also See for NDE-8503-R:
Table of Contents

Advertisement

54
en | Configuration
3.
4.7

Network

The settings on these pages are used to integrate the device into a network. Some changes
only take effect after a reboot. In this case Set changes to Set and Reboot.
1.
2.
The device is rebooted and the changed settings are activated.
4.7.1

Network Services

This page shows an overview of all available network services. Use the checkbox to activate or
deactivate a network service. Click on the settings symbol next to the network service to go to
the settings page for this network service.
Click Set to apply the changes.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
4.7.2

Network Access

If the IP address, subnet mask, or gateway address is changed, then the device is only
available under the new addresses after the reboot.
Automatic IPv4 assignment
If the network has a DHCP server for the dynamic assignment of IP addresses, select On or On
plus Link-Local to automatically accept the DHCP-assigned IP address.
If no DHCP server is available select On plus Link-Local to automatically assign a Link-Local
(Auto-IP) address.
For certain applications, the DHCP server must support the fixed assignment between IP
address and MAC address, and must be appropriately set up so that, once an IP address is
assigned, it is retained each time the system is rebooted.
Ethernet
The Ethernet options are defined in this section.
IP V4 address
IP address
Enter the desired IP address for the camera. The IP address must be valid for the network.
Subnet mask
Enter the appropriate subnet mask for the set IP address.
Gateway address
For the device to establish a connection to a remote location in a different subnet, enter the IP
address of the gateway here. Otherwise, this field can remain empty (0.0.0.0).
IP V6 address
IP address
Enter the desired IP address for the camera. The IP address must be valid for the network.
Prefix length
Enter the appropriate prefix length for the set IP address.
Gateway address
For the device to establish a connection to a remote location in a different subnet, enter the IP
address of the gateway here. Otherwise, this field can remain empty (0.0.0.0).
2021-01 | V02 | F.01U.385.211
When finished, click Set to transmit the scripts to the device. If the transfer was
successful, the message Script successfully parsed. is displayed over the text field. If it
was not successful, an error message is displayed with further information.
Make the desired changes.
Click Set and Reboot.