FLEXIDOME IP starlight 8000i
4.7.4

Network Management

SNMP
The camera supports two versions of Simple Network Management Protocol (SNMP) for
managing and monitoring network components, and can send SNMP messages (traps) to IP
addresses. The unit supports SNMP MIB II in the unified code.
Select either of the options that follow for the SNMP parameter:
If you select either of the SNMP version, but do not enter an SNMP host address, the camera
does not send messages (traps) automatically, but only replies to SNMP requests.
Select Off to deactivate the SNMP function.
1. SNMP host address / 2. SNMP host address
If you wish to send SNMP traps automatically, enter the IP addresses of one or two required
target units here.
SNMP v1 legacy
When you select SNMP v1 legacy in the field SNMP, the field SNMP traps appears.
SNMP traps
You can select which traps are to be sent.
1.
2.
3.
SNMP v3
When you select SNMP v3 in the field SNMP, the tabs User and Trap user show.
The same fields show in both tabs.
User name
Enter the appropriate user name.
Authentication protocol
Select the appropriate authentication protocol: None, MD5, or SHA1.
Authentication password
Enter the appropriate password for authentication.
Privacy protocol
Select the appropriate privacy protocol: None, DES, or AES.
Privacy password
Enter the appropriate password.
Read-only
To make this information read-only, select this check box.
UPnP
Select On to activate UPnP communication. Select Off to deactivate it.
When the Universal Plug-and-Play (UPnP) function is activated, the unit responds to requests
from the network and is automatically registered on the requesting computers as a new
network device. This function should not be used in large installations due to the large number
of registration notifications.
Note:
To use the UPnP function on a Windows computer, both the Universal Plug-and-Play Device
Host and the SSDP Discovery Service must be activated.
Bosch Security Systems B.V.
SNMP v1 legacy
SNMP v3
Click Select. A list is opened.
Click the checkboxes to select the required traps. All the checked traps will be sent.
Click Set to accept the selection.
User manual
Configuration | en
57
2021-01 | V02 | F.01U.385.211