Installation Of The Unit; Pre-Installation Checkpoints; Tools Required; Choosing A Location - Friedrich Kuhl KCL36 Installation And Operation Manual

Hide thumbs Also See for Kuhl KCL36:
Table of Contents

Advertisement

C. INSTALLATION OF THE UNIT
C.1 Pre-Installation Checkpoints
Before attempting any installation, carefully consider the
following points:
Clearances and provision for servicing. Install this unit
in accordance with local and national standards. Any
and all work must be done by authorized personnel.
IMPORTANT: Before you begin the actual installation
of your air conditioner, check your local electrical codes
and the information below. Your air conditioner must be
connected to a power source with the same alternating
current (A.C.) voltage and amperage as marked on the
name plate located on the chassis. Only A.C. can be used.
Direct Current (D.C.) cannot be used.
CIRCUIT PROTECTION – Use on single outlet circuit only.
An overloaded circuit will invariably cause malfunction or
failure of an air conditioner; therefore, it is necessary that
the electrical protection is adequate. Due to momentary
high current demand when the air conditioner starts,
use a "TIME DELAY" fuse or a HACR type circuit breaker.
Consult your dealer or power company if in doubt.
Refer to the electrical name plate located on the air
conditioner chassis (see Table E.1 to determine the
correct fuse or circuit breaker amperage for your model.
The power cord has a plug with a grounding prong and a
matching receptacle is required.
C.2 Tools Required
WARNING
Electrical Shock Hazard
Make sure your electrical receptacle has the
same configuration as your air conditioner's
plug. If different, consult a Licensed Electrician.
Do not use plug adapters.
Do not use an extension cord.
Do not remove ground prong.
Always plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
1. Power Drill
10. Flat Head Screw Driver
2.
5/32
" Drill Bit
11. Measuring Tape
3. Gloves
12. Utility Knife
4. Carpenters Level
5.
5/16
" Wrench
6.
1/4
" Wrench
7. #2 Phillips Screw
Driver
8. Putty Knife or (wood
stir stick)
9. 1/4" Nut Driver
4
1
5
2
7
3
Figure C.2 (Tools)
C.3. Choosing a Location
Installation Clearances
Improper installation of the Air Conditioner can cause poor perfor-
mance and premature wear of the unit.
Ensure that the KUHL unit is installed with proper clearances as
described below.
Ensure no obstructions or enclosures are within clearances limits to
allow for proper airflow.
Ensure no open flames, or surfaces that will exceed 1200 degrees
fahrenheit are within clearances limits.
Clearances
Top and Bottom of Unit - One (1) foot
Sides of Unit - One (1) foot
Front of Unit - Three (3) feet
Rear of Unit - Three (3) feet
6
8
WARNING
Refigeration System
Under High Pressure
Do not puncture, heat, expose to flame or
incinerate.
Only certified refrigeration technicians should
service this equipment.
R410A and R32 systems operate at higher
pressures than R22 equipment.
Appropriate safe service and handling
practices must be used.
Only use gauge sets designed for use with
R410A or R32.
Do not use standard R22 gauge sets..
CAUTION
Moving Parts Hazard
Do not operate unit out of sleeve
or with front grille removed.
Do not place hands in blower
or fan blade areas.
Failure to do so can result
in serious injury
CAUTION
Excessive Weight Hazard
Use two or more people when
installing your air conditioner.
Failure to do so can result in
back or other injury.
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kuhl khs10

Table of Contents