Startup And Operation; Final Inspection; Air Flow Selection And Adjustment - Friedrich Kuhl KCL36 Installation And Operation Manual

Hide thumbs Also See for Kuhl KCL36:
Table of Contents

Advertisement

J. STARTUP AND OPERATION
J.1 Final Inspection
Inspect and ensure that all components and accessories have
been installed properly and that they have not been damaged
during the installation progress.
Check the condensate water drain(s) to ensure that they are
adequate for the removal of condensate water, and that they
meet the approval of the end user.
Ensure that all installation instructions concerning clearances
around the unit have been adhered to. Check to ensure that
the unit air filter, indoor coil, and outdoor coil are free from any
obstructions.
Inspect the unit for any damage to the coils and tubing that could
cause a leak.
Ensure that the circuit breaker(s) or fuse(s) and supply circuit
wire size have been sized correctly. If the unit was supplied with
a power supply cord, insure that it is stored properly.
Ensure that the entire installation is in compliance with all
applicable national and local codes and ordinances having
jurisdiction.
Secure components and accessories, such as a decorative front
cover.
Start the unit and check for proper operation of all components in
each mode of operation.
Instruct the owner or operator of the units operation, and the
manufacturer's Routine Maintenance.
NOTE:
A log for recording the dates of maintenance and/ or service
is recommended.
30
J.2 Air Flow Selection and Adjustment
Airflow direction adjustment
The airflow path may be adjusted to distribute air independently from the left or
right side of the discharge opening. Each of the banks of louvers can be directed
left, right, up, or down in order to achieve the most optimum airflow positioning.
To adjust airflow direction, grab the lever in the center of the louver bank and
move it in the direction that you would like the air to be directed. Please note that it
is normal that airflow may be stronger out of one side of the louvers than the other.
Fresh air and exhaust control
Your air conditioner has the ability to bring fresh air into the room or exhaust stale
air out of the room. The control slide is found on the upper part of the unit (see
Figure 53).
TO BRING IN FRESH AIR – Move the lever to the Fresh Air
allows outside air to enter the room. This is useful in fall and spring as a means
of bringing in fresh outside air when using FAN ONLY. It can also be used in the
summer with the compressor in the Cooling Mode if you wish.
TO EXHAUST INDOOR AIR – Move the lever to the Exhaust
will allow stale air to be expelled to the outside of the dwelling. This is especially
handy in the spring or fall when indoor air tends to get stale, or after a social
gathering involving smokers, or to remove cooking odors.
BEST PERFORMANCE – Move the lever to the Re-Circulate Position.
is the most efficient mode for cooling and heating.
Figure J.2.1
position which
position. This
This

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kuhl khs10

Table of Contents