Sign In
Upload
Manuals
Brands
Friedrich Manuals
Air Conditioner
MWM24Y3J
Friedrich MWM24Y3J Manuals
Manuals and User Guides for Friedrich MWM24Y3J. We have
6
Friedrich MWM24Y3J manuals available for free PDF download: Service & Parts Manual, Service Manual, Installation And Operation Manual
Friedrich MWM24Y3J Service & Parts Manual (135 pages)
Floating Air
Brand:
Friedrich
| Category:
Air Conditioner
| Size: 26 MB
Table of Contents
Table of Contents
2
Table of Contents
3
Introduction
4
Important Safety Information
4
Personal Injury or Death Hazards
6
Model Identification Guide
7
Indoor Units
8
Outdoor Units
9
Remote Control
9
Specifications
10
Product Specifications
10
9-12K Operation Characteristics Curve
12
Operation Characteristics Curve
12
Operation Characteristics Curve
13
9-12K Capacity Variation Ratio According to Temperature
14
Capacity Variation Ratio According to Temperature
15
9-12K Noise Curve
15
18-24K Noise Curve
16
Noise Curve
16
Cooling Data Sheet in Rated Frequency
17
Heating Data Sheet in Rated Frequency
17
Cooling Capacity Charts
18
Cooling Capacity Charts
19
Cooling Capacity Charts
20
Heating Capacity Charts
21
9-12K Indoor Unit Dimensions
24
18-24K Indoor Unit Dimensions
25
9-12K Outdoor Unit Dimensions
26
18-24K Outdoor Unit Dimensions
27
Outdoor Unit Dimensions
27
Operation
28
Remote Control Button Identification
28
Remote Control Description
29
9-12K Sequence of Operation
31
18-24K Sequence of Operation
37
Sequence of Operation
42
9-12K Refrigerant System Diagram
45
Refrigerant System Diagram
45
Refrigerant System Diagram
46
Installation
47
Installation Tools
48
Installation Dimension Diagram
49
Installation Work Flow
50
Installation Parts Checklist
51
Selection of Installation Location
51
Installation of Indoor Unit
53
Installation of the Outdoor Unit
57
Leak Check, Evacuation, and Charging (Triple Evacuation)
59
Checklist and Operation Test
61
Check Unit Following Installation
61
Test Operation
61
Removal
62
Indoor Unit
62
Outdoor Unit
68
R-410A Sealed System Repair
72
Service Valves Appearance
72
Pumping down
72
Gas Charging (after Repair)
74
Components Testing
75
Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Units (15K)
75
Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Units (20K)
76
Resistance Table of Ambient Temperature Sensor for Indoor and Outdoor Units (50K)
77
9-12K Indoor Unit Printed Circuit Board Identification
78
Indoor Unit Printed Circuit Board Identification
79
Indoor Unit Printed Circuit Board Identification
80
9-12K Outdoor Unit Printed Circuit Board Identification
81
Outdoor Unit Printed Circuit Board Identification
82
Troubleshooting
83
Diagnostic Codes
83
Malfunction of Temperature Sensor F1, F2
92
Malfunction of Blocked Protection of IDU Fan Motor H6
93
Malfunction of Protection of Jumper Cap C5
94
Malfunction of IDU Fan Motor U8
95
Overcurrent Protection E5
96
Malfunction of Communication E6
97
Malfunction of Power Supply from Indoor to Outdoor Unit
98
Indoor Fan Does Not Rotate and There Is no Feedback
99
Temperature Sensor Malfunction
100
Malfunction Diagnosis of Startup Failure
101
Diagnosis of Losing Synchronism for Compressor
102
Diagnosis of Overload and Discharge Malfunction
103
Capacity Charging Malfunction (Outdoor Unit;18K, 24K, and 36K)
104
IPM Protection, Out-Of-Step Fault, Compressor Phase Overcurrent
105
PFC (Correction Power Factor) Outdor Unit Malfuction
107
Troubleshooting for Normal Malfunction
108
Wiring Diagrams
112
9-12K Indoor Unit Wiring Diagram
112
Indoor Unit Wiring Diagram
112
Indoor Unit Wiring Diagram
113
Indoor Unit Wiring Diagrams
113
9-12K Outdoor Unit Wiring Diagrams
114
Outdoor Unit Wiring Diagrams
114
Outdoor Unit Wiring Diagrams
115
Parts Catalog
116
Indoor Unit MWM09Y1J, MWM12Y1J
116
Indoor Unit MWM18Y3J, MWM24Y3J
118
Indoor Unit MWM36YJ3
121
Outdoor Unit MRM09Y1J, MRM12Y1J
123
Outdoor Unit MRM18Y3J
126
Outdoor Unit MRM24Y3J
128
Outdoor Unit MRMY36J
130
Appendix
132
Appendix 1: Reference Sheet of Celsius and Farenheit
132
Appendix 2: Configuration of Connection Pipe
132
Appendix 3: Pipe Expanding Method
133
Limited Warranty
134
Advertisement
Friedrich MWM24Y3J Service Manual (83 pages)
Brand:
Friedrich
| Category:
Air Conditioner
| Size: 18 MB
Table of Contents
Indoor Unit
14
Outdoor Unit
14
Drain Hose
34
Replace Control Board
50
Friedrich MWM24Y3J Service Manual (81 pages)
Refrigerant: R410A
Brand:
Friedrich
| Category:
Air Conditioner
| Size: 10 MB
Table of Contents
Indoor Unit
12
Outdoor Unit
12
Outlet Pipe
32
Drain Hose
32
Advertisement
Friedrich MWM24Y3J Installation And Operation Manual (68 pages)
Brand:
Friedrich
| Category:
Air Conditioner
| Size: 16 MB
Table of Contents
Table of Contents
2
Precautions
3
Parts Name
4
Emergency Operation
11
Clean and Maintenance
11
Trouble Shooting
14
Installation Dimension Diagram
18
Tools for Installation
19
Selection of Installation Location
19
Requirements for Electric Connection
20
Installation of Indoor Unit
21
Installation of Outdoor Unit
26
Vacuum Pumping
31
Check after Installation
32
Test Operation
32
Pipe Expanding Method
33
Friedrich MWM24Y3J Service Manual (83 pages)
Refrigerant: R410A
Brand:
Friedrich
| Category:
Air Conditioner
| Size: 10 MB
Friedrich MWM24Y3J Installation And Operation Manual (34 pages)
Brand:
Friedrich
| Category:
Air Conditioner
| Size: 17 MB
Table of Contents
Table of Contents
2
Operation Notices
3
Precautions
3
Parts Name
4
Remote Screen Operation Guide Buttons on Remote Controller
5
Introduction for Icons on Display Screen
5
Fan Auto
5
Timer off
5
Introduction for Buttons on Remote Controller
6
Digital Display
6
Remote Control Instructions
8
Function Introduction for Combination Buttons
9
Operation Guide
10
Replacement of Batteries in Remote Controller
10
Maintenance
11
Emergency Operation
11
Clean and Maintenance
11
Clean Filter
12
Trouble Shooting
14
Basic Trouble Shooting
14
Service and Assistance
16
Troubleshooting
17
Error Codes
17
Installation Notice
18
Installation Dimension Diagram
18
Tools for Installation
19
Selection of Installation Location
19
Requirements for Electric Connection
20
Safety Precaution
20
Grounding Requirement
20
Installation
21
Installation of Indoor Unit
21
Installation of Outdoor Unit
26
Leakage Detection
30
Vacuum Pumping
31
Test and Operation
32
Check after Installation
32
Test Operation
32
Attachment
33
Pipe Expanding Method
33
Advertisement
Related Products
Friedrich MWM09Y1J
Friedrich MWM12Y1J
Friedrich MWM18Y3J
Friedrich MWM36Y3J
Friedrich MW09Y3H
Friedrich MW09C1E
Friedrich MW12Y1E
Friedrich MW12Y3J
Friedrich MW18CJ3
Friedrich MW18Y3J
Friedrich Categories
Air Conditioner
Heat Pump
Dehumidifier
Thermostat
Air Cleaner
More Friedrich Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL