Piping:
Use at least 2" IPS PVC (51mm) pipe. Increase size if a long run is needed.
To avoid strains on the pump, support both suction and discharge pipes inde-
pendently. Place these supports near the pump.
To avoid a strain left by a gap at the last connection, start all piping at the
pump and run pipe away from the pump.
Never use a suction pipe smaller than pump suction connection.
To avoid airlocking, slope suction pipe slightly upward toward the pump.
NOTICE: To prevent flooding when removing pump for service, all flooded
suction systems must have gate valves in suction and discharge pipes.
Pump suction port should be the highest point in the suction line.
Fittings:
Fittings restrict flow; for best efficiency use fewest possible fittings.
Pool fittings must conform to International Association of Plumbing and
Mechanical Officials (IAPMO) standards.
Use only non-entrapping suction fittings or dual suction outlets installed at
least 3' (1M) apart.
Figure 2: Remote Switching For 2-Speed Pumps
TABLE I - RECOMMENDED FUSING AND WIRING DATA
Motor
Branch Fuse
HP
Rating Amps*
P4RA Models:
1-1/2-1/4
15
2-1/3
15
* Time delay fuses are recommended instead of standard fuses in any motor circuit.
Ground (Green)
L2
Common
Back of
B
motor
with
A
Terminal
Board
L1
Power Supply for
Optional Timer.
If using timer, Connect
Timer Motor to Low Speed Only
Minimum switch and timer amp rating must equal Branch Fuse
Rating given in "Recommended Fusing and Wiring Data" table.
Minimum Switch and Timer Specifications
H.P.
Model
1-1/2
P4RA6YF
2
P4RA6YG
Max Load
Voltage/
Amps
Hz/Phase
9.2/2.5
230/60/1
10.2/3.7
230/60/1
5
230
Volt
Lines
Low Spd
High Spd
Circuit
Remote
SPDT
Protector
Switch
1168 0794
V
A
230
15
1-1/2
230
15
Serv. to Motor - Dist. in Ft. (M)
0-100'
101-200'
201-300'
(0-30)
(30-60)
(60-90)
14(2)
14(2)
12(3)
14(2)
14(2)
12(3)