Installation; Additional Equipment - Shure Microflex MXW6/O-Z10 Manual

Table of Contents

Advertisement

System Settings
LED
Density Mode
External
HD
External
SD
Internal
HD
Internal
SD
Tip: If additional runtime is needed, make sure the RF Power is at the lowest setting for the size of the room. RF power is set
from MXW control software > Preferences tab.
Battery Replacement
Lithium Ion Batteries experience a linear reduction in capacity. Shure recommends establishing a battery replacement sched­
ule customized to the client requirements and replacing batteries when the capacity is no longer acceptable.
Important: After installing a new battery, reset the battery health statistics that are stored in the microphone following the steps
in Reset the Microphone Battery Statistics in the previous section.
MXW1, MXW6, MXW8 Battery Replacement
1.
Unscrew and open the battery door on the bottom of the transmitter.
2.
Remove battery by gently disconnecting the battery connector from the transmitter.
3.
Connect the replacement battery's connector to the transmitter.
4.
Replace the battery with the label facing out.
5.
Close the door and tighten the screw.
6.
Dispose of batteries properly. Check with your local vendor for proper disposal of used batteries.
MXW2 Battery Replacement
MXW2 batteries should be replaced by qualified service personnel only.

Installation

Additional Equipment

Network Cables
Audio Cables
Runtime (hours)
MXW2
MXW1
(SB902)
8
15
7
14
7
14
6
12
Use shielded Cat5e (or higher) Ethernet cables, limiting cable runs to 100 meters maximum
between network devices.
Reference the hardware kit user guide supplied with the MXW Audio Network Interface to
assemble audio cables to the connectors.
MXW2
MXW6
(SB905)
30
8
26
7
29
8
23
7
Shure Incorporated
MXW8
8
7
7
6
27/100