SECTION 4 — OPERATION

1.4 Overview of Machine

4.1 - Operating Controls and Connections
2
4
5
7
9
10
1. Mode Indication -
2. Digital Display
- Indicates welding current in Amps, welding voltage in Volts. The display also gives an indication when the machine is over temperature (-
Front View
OT -) , or the optional cooling unit is turned off (-CU-).
Power source front panel layout
3. Off/On switch
"4000" or "5000" and the machines output will be inhibited, after 4 seconds display will clear and the machine is ready to use.
1. Mode Indication
4. Output Demand Control
2. Digital Display
5. Slope control
- Operates in MIG mode only. This control alters the output voltage(V) to output current(I) relationship. This control is sometimes know as 'Arc
Control' or 'Arc Pinch Control' as it regulates the pinch effect of the welding arc.
3. Off/On switchl
6. Mode switch -
4. Output Demand Control
7. Arc force control
5. Slope control
ing electrodes (e.g. general purpose, celulosic, low hydrogen and iron powder). Turning towards maximum will increase penetration at the expense of in-
creased welding splatter, turning towards minimum will reduce penetration but the arc will be smoother and less fierce.
6. Mode switch
8. Remote control socket
plugging an external unit into the socket automatically selects remote operation and disables the internal control (4).
7. Arc force control
9. Inductance control
8. Remote control socket
welding. Too little inductance will result in excessive spatter and too much inductance will not allow the welding current to rise fast enough causing the
electrode to stub into the base metal.
9. Inductance control
10. -ve weld terminal
10. -ve weld terminal
11. +ve weld terminal
11. +ve weld terminal
12. Main 3P Isolation switch
13. Mains Input
- Three phase mains cable.
14. Auxiliary transformer supply fuse
Rear View
15. Remote supply fuse
12. Main 3P Isolation switch
16. Main supply fuse to the cooling unit (Only fitted to cooling unit version)
13. Mains Input .
17. Auxiliary Cooling unit supply fuse (only fitted to cooling unit version) -
'slow blow' rating.
14. Auxiliary transformer supply fuse
15. Remote supply fuse
16. Main supply fuse to the cooling unit
17. Auxiliary Cooling unit supply fuse
10
R5000
LEDs to display welding mode.
- Switches the machine on and off when the main 3 Phase isolation switched is in the on position. Upon switching on, the display will read
- Adjusts the machines output current in CC mode or Voltage in CV mode.
Selects welding mode when there is no remote connection.
- Operates in MMA mode only. This control alters the welding dynamics of the machine to facilitate welding with different types of weld-
- For connection of external remote control, external TIG control unit or wire feed unit. There is no switch for remote operation,
- Operates in MIG mode only. This control alters the response time of the power source and is generally used in short circuit dip transfer
- Main welding power output connector, negative polarity.
- Main welding power output connector, positive polarity.
- Switches the machine on and off.
- Fuse 3.15A slow blow, 32 x 6.3mm ceramic body.
- Protects the auxiliary supply from the remote control socket. Fuse type is 20 x 5mm glass body, 6.3A 'slow blow' rating
1
3
12
6
8
13
11
1. Mode Indication
LEDs to display welding mode.
2. Digital Display
Indicates welding current in Amps, welding voltage
in Volts. The display also gives an indication when the
machine is over temperature (- OT -) , or the optional
cooling unit is turned off (-CU-).
3. Off/On switch
Switches the machine on and off when the main 3
Phase isolation switched is in the on position. Upon
switching on, the display will read "4000" or "5000" and
the machines output will be inhibited, after 4 seconds
- Fuse 3.15A slow blow, 32 x 6.3mm ceramic body.
display will clear and the machine is ready to use.
protects the auxiliary supply to the cooling unit. Fuse type is 20 x 5mm glass body, 2A
4. Output Demand Control
Adjusts the machines output current in CC mode or
Voltage in CV mode.
R5/4000 CCCV