NewArc r1500 User Manual

Mma unit
Hide thumbs Also See for r1500:

Advertisement

Quick Links

Important Information
All persons authorised to use, repair or service the R1500 In-
verter based welding machine should read the section on
safety, before any work is undertaken. Further information is
available in publication HSG118 'Electric safety in arc welding',
which may be obtained from the Health & Safety Executive.
Please contact your distributor should you not understand any
of the information within this document.
INSTRUCTION MANUAL
To maintain continued developments of our products we reserve the right to alter specifications as quoted without prior notice
R1500
Newarc Equipment Ltd.
UK's Leading Manufacturer Of Welding Equipment
Newcastle +44 (0) 191 295 0111
Aberdeen +44 (0) 1224 771 063
www.newarc.co.uk
Description
MMA unit
Processes

Advertisement

Table of Contents
loading

Summary of Contents for NewArc r1500

  • Page 1 MMA unit Processes Important Information All persons authorised to use, repair or service the R1500 In- verter based welding machine should read the section on safety, before any work is undertaken. Further information is available in publication HSG118 'Electric safety in arc welding', which may be obtained from the Health &...
  • Page 3: Table Of Contents

    4.1 - Operation Controls and Connections___________________________________ 4.2 - Description of Controls_________________________________________________ 4.3 - Operation_____________________________________________________________ SECTION 5 — FAULT FINDING AND MAINTENANCE 5.1 - Machine Operation____________________________________________________ 5.2 - Maintenance__________________________________________________________ SECTION 6—PARTS BREAKDOWN 6.1 - Component Locations__________________________________________________ 6.2 - Parts List_______________________________________________________________ R1500...
  • Page 4 Do not work in wet or excessively humid areas • considerable time after welding opera- and do not site the R1500 on a wet surface. tions have ceased because of sparks and Avoid touching the work piece whilst welding. •...
  • Page 5: Section 2 - Specification

    The R1500 is capable of welding with all types of electrodes within the current rating of the machine, normally up to 4mm. The R1500 is able to TIG weld using a TIG torch with a built in gas valve using the 'scratch start' technique.
  • Page 6: Section 3 - Installation

    3. Installation Positioning the R1500 • Site the R1500 on a clean dry surface, preferably above ground level. • Make sure there is at least 20cm clearance at the front, rear and sides of the machine to allow good circulation of the cooling air.
  • Page 7: Section 4 - Operation

    The R1500 is suitable for welding all types of • reduce penetration but the arc will be electrodes within the current rating of the ma- smoother and less fierce.
  • Page 8: Section 5 - Fault Finding And Maintenance

    • indicates that the R1500 has overheated and the 5.2.2 Three monthly power stages of the R1500 have been shut down so you will get no current output. As per the weekly schedule, plus:- In normal climate conditions (25°C and below) the R1500 Remove the side covers from the machine.
  • Page 9: Section 6-Parts Breakdown

    SECTION 6 — PARTS BREAKDOWN 6.1 Parts Locations R1500...
  • Page 10: Parts List

    SECTION 6 — PARTS BREAKDOWN 6.2 R1500 Parts list Item no. Description Part No. Cooling fan (230Vac) M00311/A Diode module (behind bracket) (2 off) M60121 Main transformer M90136 Secondary Inductor M90133A Plastic feet (4 off) M00096 Auxiliary transformer M00305 200A Shunt...
  • Page 12 Tel: +44 (0)191 295 0111 Tel: +44 (0)1224 771063 Fax: +44 (0)191 295 0077 Fax: +44 (0)1224 724536 Website: www.newarc.co.uk e-mail: sales@newarc.co.uk Guarantee New-Arc Equipment Ltd warrants that its goods and services are guaranteed to meet the specific performance under the stated conditions of use. New-Arc cannot be held responsible for general wear and tear or for failure occurring due to misuse or abuse arising out of circumstances outside the stated conditions of use.

Table of Contents