SECTION 4 — OPERATION

1.6 Overview of Machine

4.3 - Operating Controls
1
2
1.
Wire tension screw
Adjusts the pressure on the wire feed rollers.
1. Wire tension screw
2.
MIG torch Euro connector
Adjusts the pressure on the wire feed rollers.
3.
Spool holder retaining nut
2. MIG torch Euro connector
Remove to replace wire spool and to adjust
brake adjustment screws.
3. Spool holder retaining nut
Remove to replace wire spool and to adjust brake adjustment screws.
4.
Remote control adjustment knob
5.
Earth signal return socket
4. Remote control adjustment knob
Connected to work-piece using signal lead
supplied with machine. Supplies operating
5. Earth signal return socket
voltage and earth reference to the feed unit.
Connected to work-piece using signal lead supplied with machine. Supplies operating voltage and earth
reference to the feed unit.
4.4 - MIG Welding
6. Gas inlet
It is assumed that the wire and welding torch have been fitted as per the installation part of this
A 1/4 BSP threaded inlet for connecting the shielding gas.
manual.
Set the Voltage control and wire speed controls proportional to the thickness of metal to be
7. Remote control socket
welded.
Select the welding torch mode required.
7 pin socket for connecting the remote control adjust feature to the inverter.
Ensure the gas cylinder is turned on and the flow-meter or regulator is set to give approximately 15
to 20 Litres per minute. (30 to 40 cubic feet per hour).
8. Welding power in connector
Until you are familiar with the machine it is preferable to start welding on a piece of waste material
To provide welding power and voltage to the feed unit
the same type and thickness as the work-piece, adjust the voltage control (if fitted), wire feed and
gas flow until the required welding condition is achieved.
When used with the Newarc power sources all the controls can be adjusted whilst welding without dam-
aging the machine.
14
WFU12A-ILS
3
4
6.
Gas inlet
A 1/4 BSP threaded inlet for connecting the
shielding gas.
7.
Remote control socket
7 pin socket for connecting the remote control
adjust feature to the inverter.
8.
Welding power in connector
To provide welding power and voltage to the
feed unit