YILMAZ KD 350 M Manual page 48

Table of Contents

Advertisement

Available languages

Available languages

8.2.4 Remove the saw protection connection screws (FIGURE 2 NO.95) with the aid of philips screwdriver. Remove
the saw protection Group which is set to off-position.
8.2.5 Remove the M10 bolt (FIGURE 2 NO.97) from its place with the aid of 17 mm switch. While removing the bolt,
hold from the other end of the saw shaft (FIGURE 2 NO.50) with 8 mm Allen switch.
8.2.6 Remove the string (FIGURE 2 NO.51) and saw coupling (FIGURE 2 NO.54) respectively.
8.2.7 Take out the saw blade (FIGURE 2 NO.57) carefully.
8.2.8 Install the new saw blade onto the shaft ensuring the correct rotation direction.
8.2.9 Install the guard group parts applying the reverse order as described above.
8.2.10 It is necessary to sharpen / replace the saw blade in certain intervals depending on the cutting material. If the
cut material leaves burr after the cutting operation or if the saw blade is strained, it needs to be sharpened /
replaced.
8.2.11 When replacing the saw blade, use the part of the blade washer which is appropriate for the blade shaft
diameter. The outer diameter of the blade washer is 30 and 32 mm.
8.2.12 During saw blade change operations, use protective gloves
8.2.13 Saw must be selected according to standart DIN EN 847-1
8.2.14 A saw blade rotating in reverse direction, causes danger both for the operator and the equipment. The
teeth of the saw blade would be damaged and even broken.
48

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kd 350 dKd 350 pKd 400 mKd 400 dKd 400 p

Table of Contents