MAINTENANCE AND TROUBLESHOOTING

MAINTENANCE
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the elliptical is used.
Replace any worn parts immediately.
To clean the elliptical, use a damp cloth and a small
amount of mild soap. IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
The console requires activation. If you have not
activated the console, see assembly step 7 on
page 9.
If the console does not turn on, make sure that the
power cord is fully plugged in and that the power
switch is pressed to the reset position.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the
displayed heart rate appears to be too high or too low,
see step 5 on page 15.
TABLET HOLDER TROUBLESHOOTING
If the tablet holder does
not stay in place, rotate
the tablet holder back-
ward and tighten the
screw (A) until the tablet
holder stays in place
when it is rotated to the
desired position.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback,
the reed switch should be adjusted. To adjust the
reed switch, first press the power switch to the off
position and unplug the power cord.
Next, remove the four
M4 x 16mm Screws
(not shown) from the
Large Storage Foot
(27), and then remove
the Large Storage Foot.
Then, remove the two
M4 x 16mm Screws (not
shown) from the Top
A
37
27
20
Shield (37), and use a standard screwdriver to pry the
Top Shield upward off the elliptical.
Then, look into the access opening and locate the
Reed Switch (58). Rotate the Pulley (66) until a
Magnet (41) is aligned with the Reed Switch.
Next, slightly loosen the two indicated M4 x 16mm
Screws (61). Slide the Reed Switch (58) slightly
toward or away from the Magnet (41), and then
retighten the Screws.
Then, plug in the power cord, press the power switch
to the reset position, and rotate the pulley for a
moment. Repeat these actions until the console dis-
plays correct feedback.
When the reed switch is correctly adjusted, press the
power switch to the off position, unplug the power cord
and reattach the top shield and the large storage foot.
Then, plug in the power cord.
41
61
58
66