OPERATING MODES
- ECO-SILENCE heating or cooling mode: the most economical and silent.
The HP varies the component speed to maintain an optimum sounds level and yield.
Use of 30% to 60% of the power. The COP and sound level are prioritised, the fan works at min. speed and the compressor runs to optimise the COP.
- SMART heating or cooling mode: the most intelligent mode adapts to your requirements and to the environment.
The HP varies the speed of the components to maintain an optimum power/sound level ratio.
Use of 30% to 100% of the power. The power and sound level automatically adjust depending on the external temperature and the temperature
of your pool water.
- BOOST heating or cooling mode: maximum HP power.
BOOST heating or cooling mode: maximum HP power.
The HP can vary the component speed to maintain maximum power. Use of 85% to 100% of the power to quickly increase the temperature.

TABLE OF THE DIFFERENT STATES OF THE DISPLAY

Display Meaning
Stand-by
St-by
No/insufficient water flow
FLO
HP error
AL10 / AL11
Excessive temperature difference
AL15 / AL16
between water outlet/inlet
Excessive temperature
AL18
at the compressor outlet
Temperature protection
AL17
too low in cooling mode
Communication error.
AL7 / AL8
Sensor error (water inlet)
AL3
Sensor error (water outlet)
AL4
Sensor error (evaporator)
AL5
Sensor error (compressor outlet)
AL1
Sensor error (compressor inlet)
AL2
Sensor error (ambient)
AL6
Fan error
AL9
Temperature too low
AL14
Power supply issue
AL19 / AL20
AL21 / AL22
Electronic/overheating problem.
AL23 / AL24
AL25
Phase inversion
EA08
Phase loss
EA09
14
Verification
– Check the water flow in the device.
– Check the clogging of the filter.
– Check the bypass setting.
– Check the direction of the passage of water in the
device (inlet bottom, outlet top).
Check the connections between the display and the
electronic card in the device.
Check that the sensor in question is correctly
connected..
Check the fan connections.
The outdoor temperature is < 0°C.
Have the installation checked by a
qualified technician.
Power down the device for 5 to 10 minutes, check
that it is properly ventilated, and that the air flow
is not blocked or slowed down. Power the device
back up.
Power down the device , check the global wiring and
the compressor wiring
Action required
Contact your distributor.
Wait for the temperature to
rise.
Contact your distributor.
Reconnect the phases
and ensure that the markings
are respected