STACKING INSTRUCTIONS, GCSF Oven
These stacking instructions apply when two units are being installed in a stacked arrangment only. When
an GCSF is in the top position, in a stacked assembly, the draft inducer wiring harness is needed to power
the inducer. The GCSF is the bottom position of a stacked assembly, must have the draft inducer wiring
harness removed.
When stacking an GCSF (gas) with a ECSF (electrical), put the GCSF on top to ensure proper venting of
combustion gasses.
1. Attach the feet or casters to the lower oven per the previous "Leg & Caster Installation" section.
2. Remove the Button Plug from the top right hand of the lower oven and replace it with the 1 3/4" plastic
electrical bushing provided in the stacking kit, see illustration.
3. Remove the LOWER OVEN, Draft Inducer Wiring Harness, this is not needed for the lower unit.
To accomplish this:
• Cut the 9 pin and the two single connectors coming through the top of the lower unit.
• Remove the Side Access Panel & the Terminal Block Access Panel on the lower oven.
• Disconnect the wires from the harness going to the terminal block.
• Locate the bundle of wires in the side access panel labeled "DRAFT INDUCER CONNECTION",
disconnect the wires from the oven harness at the 6 pin connector.
• The draft inducer harness can now be removed from the unit by pulling the harness from the
control side through the firewall bushing
Upper Draft Inducer Harness
Vent Shroud
Upper
Oven
Strapping Plates
Lower Draft Inducer Harness
(9 pin connector)
Lower
Oven
Button Plug
Side Access Panel
(9 pin connector)
REMOVE
Inducer
Knockout
Eye Bolt
Do Not
Remove
Inducer
Knockout
Bushing
THE OVEN WEIGHS 520 LBS (238KG).
HANDLING, INSTALLER SHOULD OBTAIN HELP AS
NEEDED, OR EMPLOY APPROPRIATE MATERIALS
HANDLING EQUIPMENT (SUCH AS A FORKLIFT, DOLLY,
OR PALLET JACK) TO REMOVE THE UNIT FROM THE
SKID AND MOVE IT TO THE PLACE OF INSTALLATION.
IL1270
Terminal Block
ANY STAND, COUNTER OR OTHER DEVICE ON WHICH
Access Panel
THE OVEN WILL BE LOCATED MUST BE DESIGNED TO
SUPPORT THE WEIGHT OF THE OVEN.
4. REMOVE THE INDUCER KNOCKOUT on the right rear
of the UPPER UNIT ONLY, prior to placing it into position.
DO NOT remove the knockout for the lower unit, doing so
will interupt proper gas venting from that unit.
5. Using the Strapping Plates (see stacking kit) secure the
two ovens together, by mounting them into the existing side
panel, using existing screws on both sides of the unit.
6. Install the vent shroud with 4 #10 sheet metal screws,
provided.
7. Remove the side access panel from the upper oven.
8. Locate the wire bundle labeled "Lower Oven Draft Inducer
Connection" in the upper oven. Pass this connection
through the plastic electrical bushing at the bottom of the
oven and into the lower oven.
EnviroZONE only: Install a 1 3/4" plastic electrical bushing,
replacing the knock-out directly behind the control cooling
fan of the lower oven.
9. In the lower oven, connect the 6 pin connector that was
passed through from the upper oven to the connection
marked "Draft Inducer Connection"
10. Replace the side access panels & attach the earthquake
strap (not included) to the eye bolt to the
illustration.
CAUTION
9
DOUBLE STACKED UNITS
upper oven, see