WATER CONNECTION
It is vital that the water supply line be thoroughly flushed with clean water before being connected
to the oven's water manifold.
After your water has been tested and meets the minimum requirements (see water requirements).
Connect water supply to 3/8" NPTM fitting located at right rear corner of the oven. Once the
water manifold and water supply are connected to the oven turn the oven ON and press the
1-shot steam button for 1 minute to remove the air and any impurities from the system.
The water must continuously be within the specifications (for this application) while this unit is
in service. Periodic testing may be needed to verify any changes in water conditions.
Plug
Gas Connection
Water Connection
Drain
Eye Bolt
DRAIN CONNECTION
Attach drain plumbing to the ¾" NPTM oven drain fitting located
at the lower rear right had corner of the oven.
Drains need to have a vent pipe attached. Typical venting is
accommodated by using a "T" off the drain pipe with an 8" to
10" open pipe in the top part of the "T". for stacking, the drains
can be manifolded together with only the top drain vented.
ELECTRICAL CONNECTION
All electrical connections must be made in accordance with
local codes or in the absence of local codes with NFPA No.
70 latest edition (in Canada use: CSA STD. C22.1)
IF A SINGLE POWER SOURCE IS TO BE CONNECTED TO
BOTH OVENS, REMOVE THE CONTROL SIDE PANELS
AND RUN THE INTERCONNECTION WIRES THROUGH
THE 1" PLASTIC ELECTRICAL BUSHING RUNNING
BETWEEN THE TWO OVENS.
The electrical service entrance is provided by several
knockouts in the top right rear corner of each oven. Line
current information can be found on the unit's data plate.
Voltage
Single
Double
Supply wire size must be large enough to carry the amperage
load for the number of ovens being installed.
WARNING
IL1276
T H I S A P P L I A N C E I S E Q U I P P E D W I T H A
3-PRONG (GROUNDING) PLUG FOR YOUR
PROTECTION AGAINST SHOCK HAZARD AND
MUST BE PLUGGED DIRECTLY INTO A PROPERLY
GROUNDED 3-PRONG RECEPTACLE. DO NOT CUT
OR REMOVE THIS GROUNDED PRONG FROM THE
PLUG.
11
UTILITY INSTALLATION
- IMPORTANT -
Phase
Total kW Amps/Line
120V
1
120V
1
0.7
5.8
1.4
11.6