General Information - WAGNER CONTROL PRO 170 Owner's Manual

Hide thumbs Also See for CONTROL PRO 170:
Table of Contents

Advertisement

GEnErAl InForMAtIon

MoDElS
Some of the graphics in this manual may not exactly match
your sprayer and spray gun. All information and instructions
given in this manual applies to all models except where noted.
The type of spray gun and length of spray hose included
depends upon the pump model you have. Refer to the chart
below for details.
Pump Model
gun Model
Control Pro 150
Hybrid (plastic/
metal handle)
Control Pro 170
Metal (all metal
handle)
Control Pro 190
Metal (all metal
handle)
The Control Pro can only be used with spray
tips, hoses or spray guns that are Control Pro
compatible. Do not use any non-Control Pro
accessories with this system.
SpECIFICAtIonS
150
Maximum
1500 PSI
Pressure
(10.3 MPa)
capacity
0.29 GPM
(1.1 LPM)
Horsepower
0.55
Max. tip
0.015
all models:
Power requirement
generator power
requirement
Overheating protection
Hose Length
25 ft.
30 ft.
50 ft.
170
190
1500 PSI
1600 PSI
(10.3 MPa)
(11.1 MPa)
0.33 GPM
0.40 GPM
(1.25 LPM)
(1.5 LPM)
0.6
0.7
0.017
0.019
15 amp minimum circuit on
115 VAC, 60 Hz current
5000 Watt
(disable idle-down feature)
This sprayer has a built-
in protective device to
prevent damage from
overheating. The sprayer
may automatically shut
down after heavy use. If this
happens, turn switch OFF (0),
unplug the sprayer and allow
to cool for 20-30 minutes and
resume spraying.
CApABIlItY
Sprays a variety of paints (oil-based and latex), primers, stains,
preservatives and other nonabrasive materials.
Do not USE!
This pump should not be used with textured materials, block
filler, lacquers, industrial enamels, or asphalt sealer or materials
containing HHC. See coating supplier if flash point is not listed
on the container.
SAFEtY FEAtUrES
Spray gun trigger lock and pressure diffuser; built-in tip safety
guard; PRIME/SPRAY knob for safe pressure release. Conforms
to UL STD 1450. Certified to CSA C22.2 NO 68.
IMportAnt ElECtrICAl InForMAtIon
Use only a 3-wire extension cord that has a
3-blade grounding plug and a 3-slot receptacle
that will accept the plug on the product.
Attention
Make sure your extension cord is in good condition. When
using an extension cord, be sure to use one heavy enough to
carry the current your product will draw. An undersized cord
will cause a drop in line voltage resulting in loss of power and
overheating.
A 14 or 12 gauge cord is recommended (see chart). If an
extension cord is to be used outdoors, it must be marked with
"SJW" or "SJTW". For example, a designation of SJTW would
indicate that the cord would be appropriate for outdoor use.
cord gauge
12
14
Wagner accessory extension cords recommended:
P/N 0090241
20 foot extension cord
P/N 0090242
35 foot extension cord
En
Maximum cord length
150 feet
100 feet
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Control pro 150Control pro 190