CDA CD 9002/1 SS Operating Instructions Manual page 41

Twin cavity dual fuel cooker
Table of Contents

Advertisement

Electrical feeder cable connection
To connect the supply cable:
- Remove the screws securing the cover "A" on the rear of the cooker (fig. 40).
- Feed the supply cable through the cable clamp "D". The supply cable must be of a
suitable size for the current requirements of the appliance; see the section "Feeder cable
section" (fig. 40).
- Connect the wires to the terminal block "B" as shown in the diagram in figure 41; or
connect the phase wires to the terminal block "B" and the earth wire to the terminal PE
as shown in figure 40.
- Take up any slack in the cable and secure with the cable clamp "D".
- Replace the cover "A".
Before effecting any intervention on the electrical parts of the appliance, the connec-
tion to the network must be interrupted.
Feeder cable section type H05RRF
230 V
(**) – Connection with wall box connection.
B
A
Fig. 40
2
3 x 2,5 mm
(**)
PE
N
L
D
230 V
L
N
PE
1
(L
)
2
Fig. 41
41