6 Electrical installation
Item
Room thermostat
In case of wireless room
(wired or wireless)
thermostat, see:
▪ Installation manual of the wireless
▪ Addendum
In case of wired room thermostat
without multi-zoning base unit, see:
▪ Installation manual of the wired
▪ Addendum
In case of wired room thermostat
with multi-zoning base unit, see:
▪ Installation manual of the wired
▪ Addendum
▪ In this case:
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Ext thermostat type
For the additional zone:
▪ [3.A] Ext thermostat type
▪ [3.9] (read-only) Control
Installation manual
16
Description
room thermostat
book
for
optional
equipment
room thermostat
book
for
optional
equipment
room
thermostat
(digital
analogue) + multi-zoning base unit
book
for
optional
equipment
▪ You need to connect the wired
room
thermostat
(digital
analogue) to the multi-zoning
base unit
▪ You need to connect the multi-
zoning base unit to the outdoor
unit
▪ For
cooling/heating
operation,
you also need to implement a
relay
(field
supply,
addendum
book
for
optional
equipment)
Item
Heat pump convector
or
or
Remote outdoor
sensor
see
Remote indoor sensor
Human Comfort
Interface
Description
There are different controllers and
setups possible for the heat pump
convectors.
Depending on the setup, you also
need to implement a relay (field
supply, see addendum book for
optional equipment).
For more information, see:
▪ Installation manual of the heat
pump convectors
▪ Installation manual of the heat
pump convector options
▪ Addendum
book
equipment
Wires: 0.75 mm²
Maximum running current: 100 mA
For the main zone:
▪ [2.9] Control
▪ [2.A] Ext thermostat type
For the additional zone:
▪ [3.A] Ext thermostat type
▪ [3.9] (read-only) Control
See:
▪ Installation manual of the remote
outdoor sensor
▪ Addendum
book
equipment
Wires: 2×0.75 mm²
[9.B.1]=1 (External sensor =
Outdoor)
[9.B.2] Ext. amb. sensor offset
[9.B.3] Averaging time
See:
▪ Installation manual of the remote
indoor sensor
▪ Addendum
book
equipment
Wires: 2×0.75 mm²
[9.B.1]=2 (External sensor = Room)
[1.7] Room sensor offset
See:
▪ Installation and operation manual of
the Human Comfort Interface
▪ Addendum
book
equipment
Wires: 2×(0.75~1.25 mm²)
Maximum length: 500 m
[2.9] Control
[1.6] Room sensor offset
EBLA04~08E2V3+E23V3 + EDLA04~08E2V3+E23V3
Daikin Altherma 3 M
4P685229-1D – 2022.10
for
optional
for
optional
for
optional
for
optional